Chapter 7: Expansion Modules
Installing An SE 1223HP Scanner
128
Psion Teklogix WORKABOUT PRO Hand-Held Computer User Manual
•
Remove the batteries. If your unit is using AC power, disconnect it.
•
Remove the end-cap at the top of the WORKABOUT PRO.
•
Slide the SW1401 switch to the left to shut off internal battery power.
With the power shut down, you can install the GSM/GPRS module and the antenna.
•
Slide the GSM/GPRS radio under the metal frame, and align the
GSM/GPRS connector with the expansion connector on the WORK-
ABOUT PRO. Apply slight pressure to snap the module into place on the
hand-held.
•
Use the screws provided to secure the module in place.
•
Fit the antenna at the top of the unit making certain that the antenna
contacts are aligned with the contacts on the GSM/GPRS module.
•
Use the screws provided to secure the antenna on the metal frame.
Figure 7.7 An Installed GSM/GPRS Module
•
Slide the SW1401 switch to the right to turn power back on.
•
Replace the end-cap, back plate and batteries.
7.1.6 Installing An SE 1223HP Scanner
The SE 1223HP scanner is the internal scanner module available with the
WORKABOUT PRO. To install it:
•
Remove the batteries. If your unit is using AC power, disconnect it.