Configuration and Use
PowerPlay IPC-8000 and IPC-9000
4826 Sterling Drive, Boulder CO 80301
15-052-01-1-DOM-B
PH: 720.406.8946 [email protected] www.psaudio.com
©2010 PS Audio International Inc. All rights reserved.
Reboot
The outlet is ALWAYS ON, but may be rebooted through the web interface
Auto Reboot
The outlet is ALWAYS ON, may be rebooted from the web interface, and automatically
reboots when no web connection is detected for 10 minutes. When Auto Reboot is
selected you may use the on and off delays to sequence power of Auto Reboot outlets
individually.
UPS Priority
When PowerPlay is connected to a PS Audio PowerPack battery backup you may control how
each outlet shuts down in a battery backup situation.
Using the drop box you may select one of the following options:
None –
No battery backup is provided to these outlets in order to quickly reduce the
load and extend battery life. Use this setting for amps, subwoofers and other large draw
devices.
Normal –
Some battery protection is provided, but outlets turn off when UPS reaches
25% battery remaining. Use this setting to safely shut down devices such as projectors
or any other device which require some user interaction to properly shut down
Critical –
Full battery protection, outlets remain powered until battery runs out. Use this
setting for network critical or other devices which need to remain powered as long as
possible.
Important: Changes made in the configuration tab must be confirmed by clicking on the
Save
button at the bottom of the page.