Commissioning
Before commissioning, check the proper condition of the unit:
✓
Ropes for visible damage, especially to the respective end attachment.
✓
The detent button must engage automatically.
✓
Snap hook on function. The eyelet must close automatically.
✓
Mounting on wall units.
✓
Stability of floor-standing devices.
✓
Protective cladding - present or damaged.
✓
Screw connections - check for tight connection.
✓
Welded joints - visual inspection.
✓
Motion limitation, if available as an option.
✓
Accessories available/functional
For cable columns S1 as wall model (Art. 10120100, 10120300)
Since the type of the walls to which the supplied cable columns are attached, can differ considerably.
proxomed only supplies wall attachments for walls with load-bearing properties.
We strongly recommend that the mounting has to be carried out by a specialist company in order to
ensure safety during training. The service load that results can be over 2kN. Heavy-duty anchors of
strength M8 with corresponding screws must at least be used. For safety reasons, check the fastening of
the screws at regular intervals (1-2 months).