FAULT
CAUSE
REMEDY
Improper hydraulic oil
viscosity.
Check oil quality, make sure that
the oil in both machines is of the
same type. If necessary change
oil in tractor or in trailer.
Insufficient tractor hydraulic
pump output, damaged
tractor hydraulic pump.
Check tractor hydraulic pump.
Damaged or contaminated
cylinder
Check cylinder piston rod
(bending, corrosion), check
cylinder for tightness (cylinder
piston rod seal), if necessary,
repair or replace the cylinder.
Excessive cylinder load.
Check and reduce cylinder load, if
necessary.
Incorrect hydraulic
system operation.
Damaged hydraulic
conduits.
Check and ascertain that hydraulic
lines are tight, not fractured and
properly tightened. If necessary,
replace or tighten.