Data
Value Unit
Medium temperature:
-10...+45 °C
Sound pressure level:
1000 ... 2500 m/s
CAUTION!
Measuring capability of feed chemicals
–
All liquids that conduct ultrasound waves can be measured.
–
Any liquids that poorly conduct ultrasound waves cannot be measured, such as sodium
hydroxide solution (NaOH) at concentrations above 20%.
–
First test measuring capability with emulsions and suspensions.
Ambient conditions
Data
Value Unit
Minimum storage and transport temperature
-10 °C
Maximum storage and transport temperature
+50 °C
Minimum ambient temperature during operation
-10 °C
Maximum ambient temperature during operation
+50 °C
Maximum air humidity*
95 % relative
humidity
*non-condensing
Materials
Component
Material
Measuring pipe
PVDF
Seals, hydraulic
- see "Identity code"
Housing
PPE+GF20
Screws etc.
A2
Electronics
Electronic components
Technical Data
67