8.4.2.3 “Current output” menu
(with identity code characteristic “signal output” “1”, “3” and “4”)
P
P
P
P
P
P
P
P
B0496_3
settings
Current output
Current range
4...20 mA
Current output
Signal current
flow unit
mL/h
0/4 mA value
0.68 mL/h
20 mA value
897.65 mL/h
P
damping
30.00 s
Current output
Error current
Error current
switch on
P
Error current
23 mA
P
Current output
controlled pump
P
P
Simulation
Simulation
10.0 mA
In the
‘current output’ menu, the standard signal output (mA) can be set either to output the current
flow, an error signal, or to interact with the control module of a metering pump delta
®
.
In the
‘signal current’ menu, a setting can be
entered to determine how the DulcoFlow
®
out‐
puts the current flow via the current output to
an external unit.
You can enter any behaviour for the current
signal proportional to the flow. To do so, for
example enter any two points P1 (4 mA, Q1)
and P2 (20 mA, Q2) (Q1 is the flow at which
the DulcoFlow
®
outputs 4 mA.); this means that
one line is specified and hence the behaviour:
Set up
39