If this is not the case, proceed in accord‐
ance with the handling instructions,
which can be found after the tips.
10.
Check whether the frequency signals
and the mA signals of the device have
the expected effect if these signals are
being used.
If this is not the case, proceed in accord‐
ance with the handling instructions,
which can be found after the tips.
Press [P] to acknowledge if the
metering pump goes into fault mode
during start up.
For use with the metering pump delta
®
set to "dosing" - "set-up" (discharge
stroke)" - "fast".
Operation as a dosing monitor
1.
Under
‘set-up
è
set counter output’ to
‘stroke feedback’ .
2.
In the menu
‘calibration’ set the ‘stroke
feedback’ - see
brating “stroke feedback”’ on page 41
Operation as a flow meter
1.
In the menu
‘calibration’ calibrate the
‘quantity’ - see
2.
Check whether the displayed values are
plausible.
Function "transmit flow value Q"
(for identity code characteristic "signal output"
"1")
1.
Set up the desired values under
‘Settings
è
Current output
è
Signal current’ - see
8.4.2.3 ‘“Current output” menu’
2.
Check whether the displayed values are
plausible.
(for identity code characteristic "signal output"
"2")
1.
Set up the desired values under
‘Settings
è
Counter output
è
Pulse/frequency
è
Signal output’ -
see
Chapter 8.4.2.2 ‘“Counter output”
2.
Check whether the displayed values are
plausible.
Function "transmit error signal"
(for identity code characteristic "signal output"
"1" and "3")
1.
Under
‘set-up
è
current output
è
error current’ set the desired error
result and set the
‘error current’ .
2.
Cause the error to occur and check
whether everything functions as desired.
(for identity code characteristic "signal output"
"2" and "3")
1.
Under
‘set-up
è
counter output
è
puls/freq.
è
error output’ set the
desired error result.
2.
Cause the error to occur and check
whether everything functions as desired.
Start Up
56