8.4.2.4 “Sensitivity” menu
P
P
B0501
Set-up
Sensitivity
Sensitivity
normal
The sensitivity of the unit to disturbances, like air bubbles, can be reduced in the “Sensitivity” menu.
At the same time, this also reduces the measuring sensitivity.
Sensitivity setting
Sensitivity to air bubbles
Measuring accuracy
normal
high
high
...
...
...
Level 4
poor
poor
8.4.2.5 “Pump type” menu
P
P
B0636
Settings
Pump type
Pump type
Solenoid meter.pump
The pump type needs to be entered in the “Pump type” menu.
8.4.2.6 “service” menu
P
P
B0229
set-up
service
service code
0000
The “service” menu is password protected and only for service.
8.4.3 “Calibration” main menu
main menu
calibration
The flow measurement can be calibrated or the
stroke feedback set up in the “calibration”
menu.
8.4.3.1 Calibrating “stroke feed‐
back”
8.4.3.1.1 For “volume”
The permitted range for the stroke volume V/H
can be specified in this menu. If the stroke
volume moves outside of this range, for
example due to an altered back pressure, the
DulcoFlow
®
no longer gives any stroke feed‐
Set up