Disposal
No power.
Water tank full.
Ambient temperature too low.
Ambient temperature lower than the set
temperature cooling mode.
There is direct sunlight.
Doors and windows are open or there are
other heat sources.
Air inlet or air outlet clogged.
Appliance not on a flat surface.
The batteries are dead.
Pipe temperature sensor failure.
Room temperature sensor failure.
Anti-frost protection.
The air-conditioner is not
operating.
Poor cooling.
Noisey.
The compressor does not
work.
The remote control does
not work.
Connect the unit to a live power socket
and turn it on.
Drain the water stored in the unit.
Ambient temperature too low.
It is recommended that this unit be
operated at 5-32°C.
Increase the set temperature above the
ambient temperature.
Draw curtains.
Close doors and windows and remove
other heat sources.
Remove the obstruction.
Place the appliance on a flat surface.
Wait three minutes until the temperature
decreases and then turn on the unit.
Bring the remote control closer to the
appliance and ensure that the remote
control is pointing toward the receiving
head of the remote control.
Replace the batteries.
Arrange for a professional to check the
pipe temperature sensor and related
circuits.
Arrange for a professional to check the
room temperature sensor and related
circuits.
Appliance returns to operating at chosen
settings once the internal pipe
temperature exceeds 8°C.
Clean filters.
Dirty filters.
Initiation of overheat protection.
Too far from appliance.
The remote control is not pointing towards
the receiving head of the remote control.
Display showing E1.
Display showing E2.
Display showing E4.
English | 16
Kein Strom.
Voller Wassertank.
Die Raumtemperatur ist zu gering.
Eine Raumtemperatur unter der eingestell-
ten Temperatur im Kühl-Modus.
Türen und Fenster sind offen oder es sind
andere Wärmequellen vorhanden.
Die Filter sind verschmutzt.
Lufteinlass/Luftauslass ist verstopft.
Es gibt direkte Sonneneinstrahlung.
Der Überhitzungsschutz ist aktiv.
Die Frostschutz-Funktion ist aktiv.
Issue
Cause
Die Klimaanlage
funktioniert nicht.
Kühlung funktioniert nicht
richtig.
Laute Geräusche.
Der Kompressor
funktioniert nicht.
Resolution
Schließen Sie das Gerät ans Stromnetz
an und schalten es ein.
Entleeren Sie das angesammelte
Wasser.
Wir empfehlen einen Betrieb dieses
Geräts bei Temperaturen zwischen
5-32°C.
Erhöhen Sie die eingestellte Temperatur
über die Umgebungstemperatur.
Schließen Sie Fenster und Türen und
entfernen andere Wärmequellen.
Filter reinigen.
Entfernen Sie alle Fremdkörper.
Vorhänge zuziehen.
Lassen Sie den Kompressor drei Minuten
lang abkühlen, bevor Sie das Gerät
wieder einschalten.
Gehen Sie mit der Fernbedienung näher
an das Gerät heran und richten Sie die
Fernbedienung direkt auf den Sensor
am Gerät.
Batterien ersetzen.