Machine Manual
Orion
CTS Flex Stretchwrapper
Revision 3.0
Troubleshooting
25 July 2016
Page 4-8
Carriage Lift
(Up & Down)
Carriage Will Not Move Up Or
Down (In Either Manual Mode
Or During An Auto Wrap
Cycle)
Blown Fuse.
Locate carriage lift control fuse. Remove
fuse and check continuity.
Bad Fuse? Replace with correct type.
Motor failure.
Perform motor test per motor manufac-
turer's recommendation.
Replace Motor as needed.
Reducer failure.
Remove Carriage Lift reducer-separate
motor from reducer. Rotate input shaft and
check for binding
Replace reducer as needed.
Carriage Will Not Move Up Or
Down
(In Auto Wrap Cycle Only-but
Works Fine In Manual Mode).
Auto-height photocell positioned
incorrectly.
Check the position of the Auto-height
photocell. Make sure it is aimed at the
load. If the load is too short for the photo-
cell to see, the carriage will not move up-
this is normal.
Re-Aim the photocell correctly.
Auto-height sensor has failed.
Check for 24VDC at the sensor. Check for
24VDC switching on the return wire to
PLC at the sensor.
No VDC Switching out at the sensor?
Replace sensor.
Wiring in the Auto-height sensor
circuit has failed.
Run a continuity test on wiring from the
sensor to the PLC and 24VDC supply
rails.
No continuity on any wire?= repair or
replace wiring.
Table 4-1. Troubleshooting Chart (Continued)
PROBLEM
POSSIBLE CAUSE
SOLUTION
Summary of Contents for Orion CTS Flex Stretchwrapper
Page 114: ...Machine Manual Orion CTS Flex Stretchwrapper Revision 3 0 Maintenance 25 July 2016 Page 5 10...
Page 118: ......
Page 119: ......
Page 120: ......
Page 121: ......
Page 122: ......
Page 123: ......
Page 124: ......
Page 125: ......
Page 126: ......
Page 127: ......
Page 128: ......
Page 129: ...DC OK Adjust 24V 2 5A L N 100 240V 1 5A 50 60Hz G R...
Page 130: ......
Page 131: ......