Orion
Machine Manual
Revision 3.0
CTS Flex Stretchwrapper
25 July 2016
Troubleshooting
Page 4-7
Carriage Lift
(Up & Down)
Carriage Will Not Move Up Or
Down (In Either Manual Mode
Or During An Auto Wrap
Cycle)
A False (No visible obstruction)
lift belt error has occurred.
Remove upper-rear access panel on the
back of the mast. Observe the position of
the lift belt roller switch at the top, inside
of the mast. The belt should be between
the metal frame and the switch's roller
lever. The lever roller should be activated.
If the belt is placed incorrectly, re-set belt
so that it is between the frame and the
switch's lever roller. The switch may need
to be re-positioned as to not give a false
signal.
Current Limiter in the carriage lift
VFD is activating.
Check for a mechanical bind in the car-
riage lift mechanicals, such as, worn belt
wheel bearings incorrectly aligned belt or
carriage safety cam-locks.
Identify and repair or replace worn parts.
Maximum speed setting on the
VFD is incorrect.
Review the maximum frequency parame-
ter settings in the VFD. Refer to the sup-
plied VFD Manual for procedure.
Refer to the VFD manual and the Orion
parameter settings sheet supplied with the
machine for maximum frequency settings.
Machine's supply voltage is too
low.
Check AC voltage (at the On-Off switch
terminals) while the machine is running
under load.
If voltage drops below 115, the supply is
not strong enough to run the machine cor-
rectly. Contact plant electrician. Do not
use household extension cords with the
machine.
Loose connections in the carriage
lift circuit.
Remove power from machine. Check for
loose connections in the carriage lift cir-
cuit such as; Primary supply to the Lift
VFD, Secondary supply from the VFD to
the drive motor and all connections in
between.
Re-seat all loose connections. Tighten
connections correctly.
Table 4-1. Troubleshooting Chart (Continued)
PROBLEM
POSSIBLE CAUSE
SOLUTION
Summary of Contents for Orion CTS Flex Stretchwrapper
Page 114: ...Machine Manual Orion CTS Flex Stretchwrapper Revision 3 0 Maintenance 25 July 2016 Page 5 10...
Page 118: ......
Page 119: ......
Page 120: ......
Page 121: ......
Page 122: ......
Page 123: ......
Page 124: ......
Page 125: ......
Page 126: ......
Page 127: ......
Page 128: ......
Page 129: ...DC OK Adjust 24V 2 5A L N 100 240V 1 5A 50 60Hz G R...
Page 130: ......
Page 131: ......