Machine Manual
Orion
CTS Flex Stretchwrapper
Revision 3.0
System Operation
25 July 2016
Page 3-48
CARRIAGE GATE
OPEN
The carriage gate is currently open.
Close the carriage to allow oper-
ation. Check the interlock
switch.
HOMING MACHINE
The machine is homing.
Allow the machine to home prior
to starting.
LOW AIR PRESSURE
The machine pneumatic pressure is low.
Check the pneumatic supply.
Ensure 80 PSI is available.
PRESS START BUTTON
TO RESET CONTROL
POWER
The machine is not reset.
Press Start to reset control power
prior to starting.
MOVING TO BOTTOM
OF LOAD
The carriage is moving to the bottom of the load.
This is for informational pur-
poses only. No correction neces-
sary.
MOVING TO TOP OF
LOAD
The carriage is moving to the top of the load.
This is for informational pur-
poses only. No correction neces-
sary.
CARRIAGE
OBSTACLE DETECTED
- CLEAR & PRESS
RESET
The obstacle detection is tripped.
See “Carriage Obstacle Detect
Error Recovery” on page 3 - 2.
READY TO WRAP -
PRESS & HOLD START
BUTTON
The machine is reset and ready to run.
Press and hold the start button
for the amount of time set in the
parameters to start the machine.
APPLYING
REINFORCEMENT
WRAPS
Reinforce wraps are currently being applied.
Once the reinforce wraps are
completed, the machine will
continue its cycle.
TOWER OBSTACLE
DETECTED
The tower has an obstruction.
Check for a mechanical bind.
Clear the cause of the fault.
Reset and restart, when ready.
APPLYING BOTTOM
WRAPS
The bottom wraps are currently being applied.
This is for informational pur-
poses only. No correction neces-
sary.
WRAP CYCLE IS
COMPLETE
The wrap cycle is now complete.
Remove the load, when ready.
Table 3-32. The Information and Alarm Displays (Continued)
MESSAGE
DESCRIPTION
CORRECTION
Summary of Contents for Orion CTS Flex Stretchwrapper
Page 114: ...Machine Manual Orion CTS Flex Stretchwrapper Revision 3 0 Maintenance 25 July 2016 Page 5 10...
Page 118: ......
Page 119: ......
Page 120: ......
Page 121: ......
Page 122: ......
Page 123: ......
Page 124: ......
Page 125: ......
Page 126: ......
Page 127: ......
Page 128: ......
Page 129: ...DC OK Adjust 24V 2 5A L N 100 240V 1 5A 50 60Hz G R...
Page 130: ......
Page 131: ......