Machine Manual
Orion
CTS Flex Stretchwrapper
Revision 3.0
System Operation
25 July 2016
Page 3-52
LOW AIR PRESSURE
The machine pneumatic pressure is low.
Check the pneumatic supply.
Ensure 80 PSI is available.
BRUSH AND CUTTER
NOT HOME
The brush and cutter are not home.
Cycle the brush and cutter.
Check why the brush and cutter
can’t reach the home position.
OBSTACLE DETECTED
The tower has an obstruction.
Check for a mechanical bind.
Clear the cause of the fault.
Reset and restart, when ready.
MULTISTRETCH VFD
NOT READY
The indicated VFD is not ready to run.
Check the fault code on the VFD
display in the electrical cabinet.
See VFD manual for fault code
information.
MAIN DRIVE VFD NOT
READY
CARRIAGE VFD NOT
READY
(NAME) CONVEYOR
VFD NOT READY
X2X
COMMUNICATION
ERROR
There is an X2X communication fault, press and
release the E-stop button to clear the fault.
Contact Orion Packaging if
problem persists.
RS485
COMMUNICATION
ERROR
There is an RS485 communication fault, press
and release the E-stop button to clear the fault.
Contact Orion Packaging if
problem persists.
Table 3-33. The Information and Alarm Displays (Continued)
MESSAGE
DESCRIPTION
CORRECTION
Summary of Contents for Orion CTS Flex Stretchwrapper
Page 114: ...Machine Manual Orion CTS Flex Stretchwrapper Revision 3 0 Maintenance 25 July 2016 Page 5 10...
Page 118: ......
Page 119: ......
Page 120: ......
Page 121: ......
Page 122: ......
Page 123: ......
Page 124: ......
Page 125: ......
Page 126: ......
Page 127: ......
Page 128: ......
Page 129: ...DC OK Adjust 24V 2 5A L N 100 240V 1 5A 50 60Hz G R...
Page 130: ......
Page 131: ......