625-525revG-EN
3
Printed in USA 4/06 © 2006
Steamer
625-OS
Temperature Calibration
A. Press and hold the TEMPERATURE button. The display will
show the current temperature setting for Celsius (C) or
Fahrenheit (F).
B. While holding the TEMPERATURE button, press the C/F
button to change the setting between Fahrenheit and Celsius.
C. Release the TEMPERATURE button to store the new value.
1
A. Press the UP or DOWN Arrow button until the temperature
readout matches the calibration reading.
B. Press the RAPID STEAMER Logo button to store the desired
calibration and exit CAL TEMP Mode.
3
NOTE: Pressing the PRODUCT 3 button at any time exits the Program
Mode without storing the change.
The CAL TEMP Mode is used to calibrate the platen temperature
with an external meter connected to the meter plug inlet on the
bottom right side of the unit. Add ± 5°C (± 10°F).
2
A. Press and hold RAPID STEAMER Logo button and immediately press
and hold the TEMPERATURE button. Hold for 6 seconds.
B. The display now shows the current calibration temperature.
C. Press the PRODUCT 2 button to
zero any previous calibration
offset value. The display will now
show the platen temperature
without any calibration offset.
Factory Presets
Loading factory presets restores the unit to factory settings and voids all
user programmed information.
A During power up, press and hold both PRODUCT 1 and PRODUCT
4 buttons within 3
seconds. The display
will flash PRESETS
LOADED.
B. Release both buttons.
Default Factory Presets:
ON OFF
Cycles
Delay
.6
1.5
7
6
View Software Version
. VERS XX.XX
Press and hold the RAPID STEAMER Logo button first, then press and
hold the START button.
The display will show the current firmware version.
Manual Reset
A hi-limit thermostat will turn off electrical power to the platen and control
circuits if the unit overheats.
Turn the unit off and allow to cool (approximately 10 – 15 minutes).
A manual reset is located on the back of the unit. Once the unit has
cooled sufficiently, remove the cap and press the manual reset to restart
unit. Replace the manual reset cap.
Manual Reset
NOTE: If the unit continues
to shut off due to
overheating, contact your
authorized Prince Castle
Service Agency.