64
PROGRAMMING MANUAL
100962 G PUBLICATION DATE 24 JUN 2008.DOC
T
THE SPRAY SEQUENCE
•
Water or Liquid is injected at Distribution or Low Spin Speed
•
No standard water inlets can be programmed in this function.
•
The spray inlets can only be programmed at the X & XF - type machines.
•
On the other machines the liquid will be injected based on soap supply programming.
•
The suggested drum speed value depends on the machine
type.
•
The drum speed value can only be programmed within
certain limits.
[50 – 150] RPM and [400 – 600] RPM
•
The default Spray speed value is 120 RPM.
•
Insert the desired speed value. Press the
ENTER
button for
confirmation.
•
Speed selection at the Spray Sequence :
1-motor type washing machine : Low spin speed
£
Low spin speed is the default setting
£
No selection is needed
2-motor type washing machine : Distribute or Low Spin
Speed
£
Distribute is the default setting.
£
Select the Speed Selection from the list and press the
ENTER button for confirmation.
•
Only available on washing machines with both : a normal
Open and a normal Closed Drain valve.
•
As water will be drained at the Spray sequence, it must be
possible to select the wished drain valve 1 or 2.
•
The default Drain valve is Drain valve 1.
•
Select the desired Drain Valve by pressing the ARROW
LEFT or RIGHT button.
•
Press the ENTER button for confirmation.
•
If you don‘t want to get into the supply sub-menu, press the
ARROW DOWN button.
•
Press the ENTER button to get into the supply sub-menu.
•
Default: all the supplies are switched off.
•
Extra supplies can only be programmed if the selection in the
Prewash
| Wash | Cooldown | Rinse |
Final Rinse
| Soak |
Flush
|
Spray
| No wash
P:Pr XX Step XX
RPM : _ _ _
P:Pr XX Step XX
Supply ?
P:Pr XX Step XX
Drain valve : 1
1
| 2 | 1+2
P:Pr XX Step XX
Spd : Distribute
Summary of Contents for FF10
Page 2: ......
Page 7: ...100962 G PUBLICATION DATE 24 JUN 2008 DOC PROGRAMMING MANUAL 5 ...
Page 39: ...100962 G PUBLICATION DATE 24 JUN 2008 DOC PROGRAMMING MANUAL 37 ...
Page 134: ......
Page 135: ......