32
PROGRAMMING MANUAL
100962 G PUBLICATION DATE 24 JUN 2008.DOC
•
Some machines function with water recovery and are
equipped with a second drain valve.
•
If this second drain valve is a Normal Closed drain valve
then, drain valve 2 must be Selected Yes.
•
Confirm by pressing the ENTER button.
Machines with Front Soap Hopper Only.
•
By selecting “Water Recycle Inlets” Yes its possible to
program 3 extra water inlet valves I4, I5, I6 in the wash
sequences and 3 extra outlet valves for water recycling
combined with pump in the drain-extraction sequences.
•
No is the default value.
•
Yes : Extra water recycle Inlets and Outlets can be selected
in the Program menu’s.
No : Extra water recycle Inlets and Outlets are switched off
in the Program menu’s.
•
Confirm by pressing the ENTER button.
Attention !
In some machines extra electrical components have to be
added as an option to complete the electrical installation.
Only for washing machines with Front Soap Hopper.
•
If the operator doesn‘t want to use the Soap Hoppers and
has connected the electrical signal of the hopper to an
external liquid soap supply pump, the signal must be set on
Liquid.
•
Liquid can be selected by pressing the ARROW Right
button.
•
Supply Sign A corresponds with the First soap hopper.
Supply Sign B corresponds with the Second soap hopper.
…
Supply Sign E corresponds with the Fifth soap hopper.
•
By selecting liquid, no pulse will interrupt the soap supply
signal.
•
Confirm by pressing the ENTER button.
C:Drain
Valve 2: No
C:Supply Sign
A: Hopper
C:Water Recycle
Inlets : No