Test of the zones

 

. entry into test mode: before supplying power to the panel remove the wires 

to terminals "Y" and "G" and connect jumper between them.

 

. Upon successful entry into test mode the remote led for the mode of the 

control Panel "status" does not light for about 5 seconds after the power. the 5 

leds for indicating the level of GsM radio signal show running lights for about 5 sec-

onds, then proceeds to test mode.

 

3. in the presence of any active zone the remote led "status" lights and the 

corresponding of the 5 leds for the level of GsM radio signal lights as follows:

Zone  - lights the led "" and the remote led "status".

Zone  - lights the led "" and the remote led "status"

Zone 3 - lights the led "4" and the remote led "status"

Zone 4 - lights the led "8" and the remote led "status"

Zone 5 - lights the led "6" and the remote led "status"

 

4. With activated "tamper" (interruption) or fault (short circuit) for a zone, the 

corresponding led flashes.

 

5. in the presence of "tamper" the indication for active zone goes off.

 

6. in the absence of an active zone the running lights continues.

 

7. signal "Gong" is generated for the zones for which it is configured.

 

8. this mode is released after turning off the power and removing the jumper 

between terminals "Y" and "G".

Configuration parameters

 

. times for entering in any delay zone and exit time.

 

. duration of the turning on of the high current output (siren).

 

3. delay of transmission of signals for stopping and restoring the battery 

charge.

 

4. GsM numbers - up to 6 pcs.

 

5. for each GsM number: options for sending sMs alarms, for sending sMs 

for faults, for permits for turning on and off module in armed mode and for format of 

the returned response (sMs or call).

 

6. names of each of the zones, which can be used in sMs. each description 

can contain up to 3 characters.

 

7. type of each zone: turned off, delayed, instant, 4-hr., interior, hidden 

switch.

 

When the zone is turned off, its condition has no effect on the station.

Summary of Contents for PC GSM 612

Page 1: ...PC GSM 612 HOME ALARM GUIDANCE FOR INSTALLERS...

Page 2: ...the codes 10 c GSM parameters 10 d GPRS parameters 11 e Measured voltage at the terminals of the different kinds of zones 11 6 Inclusion exclusion under arming 11 7 Armed mode 12 8 Announcement 13 9...

Page 3: ...n to turning on off at arming by telephone permission to send SMS in the failure restore of the AC power GSM number to check the validity and limits of a prepaid SIM card 4 Powerful output 12V 1A for...

Page 4: ...Warning The events of the twin zones are transmitted to the centre by num bers to which was added 10 for example the twin zone 3 will be displayed as a zone 13...

Page 5: ...rnal transformer Bt plus and minus of the battery Ld LED Status for indicating of operating mode connects between Ld and Aux 12V with a plus to the Aux Aux 12V power supply for external sensors two lu...

Page 6: ...chassis minus of the power supply Z5 Zone 5 balanced connects between Z5 and ground HK Zone 6 balanced connects between HK and ground Connecting of the zones is done in the following ways NC unbalanc...

Page 7: ...tion or fault short circuit for a zone the corresponding LED flashes 5 In the presence of Tamper the indication for active zone goes off 6 In the absence of an active zone the running lights continues...

Page 8: ...f the zones in a separate scheme 9 Activation time of each of the zones with step 10 ms 10 Permission for arming at active instant or delay zone bypass upon activa tion 11 Method of switching on and o...

Page 9: ...e 0 Off 1 Delay 2 Instantaneous 3 24 hours 4 Interior 5 Arming hidden switch Active state and balance measured voltages 0 NC unbalanced 0 5V 1 NO unbalanced 4 5V 2 NC balanced 2 9V 3 NO balanced 2 9V...

Page 10: ...nfiguration code homeal GSM parameters Notification GSM 1 GSM 2 GSM 3 GSM 4 GSM 5 GSM 6 SMS on alarm Yes Dial at alarm No Dial at inclusion exclusion under arming Yes Permission for inclusion exclu si...

Page 11: ...Alarm Alarm Both Tamper Trouble 0 NC unbalanced 0 5V 5V 1 NO unbalanced 5V 0 5V 2 NC balanced 2 9V 4 5V 0 5V 3 NO balanced 2 9V 0 5V 5V 4 NC bal with tamper 2 9V 4 3V 5V 0 5V 5 NO bal with tamper 4 3...

Page 12: ...rns off the system generates six squawks and the panel is not included in security 6 The zones status is monitored only at the time of inclusion of the hidden switch If the zone is activated or restor...

Page 13: ...4 Continuous monitoring of the battery voltage if for 30 minutes in all checking the voltage is 10 5V a message is sent for diluted battery LOW BATTERY TROU BLE ALARM and respectively if for 30 minute...

Page 14: ...The module sends an SMS to the specified number System ARMED zones A N N A N N AC Power On System disarmed zones N A N N N N AC Power Off wherein A means Active Active zone the zone is activated and N...

Page 15: ...shes two or three times quickly during a half second there was an alarm the panel is in alarm the siren is turned on Flashes once per second passes entry time or exit time Level 5 pcs green LEDs 1 2 4...

Page 16: ...rk Flashing 64ms ON 3000 ms off has detected a network Flashing 64ms ON 300 ms off GPRS communication Green LED on the PCB The green LED lights in the presence of AC power Configuring There are two wa...

Page 17: ...menu they are written in small letters Of each byte in command mode the module returns an echo 8 Alarm Parameters Codes Parameters and GSM Parameters are the three menus for programming 9 After the co...

Page 18: ...arm Zone 5 Description z5 Zone 5 Alarm Zone 6 Description z6 Zone 6 Alarm Factory Default fd Read RAM Data rd To Main Menu mm 16 The duration of the signal Gong Chime is in 10 ms steps 17 Forced allow...

Page 19: ...ters not just num bers 23 After entering from the main menu of gp the module sends GSM Parameters APN Address aa internet vivatel bg PDP Address pa 0 0 0 0 Server TCP IP 1 s1 192 168 1 51 Server Port...

Page 20: ...is very cumbersome it takes more than 30 seconds Better is the announcement by GSM for arisen events to be done via SMS 26 GSM Mode Options these are the options for the operating mode of GSM if GPRS...

Page 21: ...details the device responds with OK For example Serial Number serial number of the module 6 digits sn 77 77 77 the answer is 40 Command for reading rd After its submission the display shows RAM Data...

Page 22: ...ement of individu al commands does not matter important is just to begin with code and the correct configuration code and ends with go If at the end there is a number to which the module to send an SM...

Page 23: ...3 If must be entered a hexadecimal number compulsory is to be entered two characters even if the first is zero If the hexadecimal number contains a letter it must be small Latin a b c d e f When enter...

Page 24: ...ve state and for balance of the sensors see the figure Variants of connecting zones normally open or closed contact balanced or unbalanced with tamper or without tamper paired or single by default all...

Page 25: ...phone 10 Arm and disarm by configured method The LED Status should be lit at arming and go off on disarming 11 If at the time of arming with a secret switch there is an active zone disarm ing is not...

Reviews: