Test of the zones
. entry into test mode: before supplying power to the panel remove the wires
to terminals "Y" and "G" and connect jumper between them.
. Upon successful entry into test mode the remote led for the mode of the
control Panel "status" does not light for about 5 seconds after the power. the 5
leds for indicating the level of GsM radio signal show running lights for about 5 sec-
onds, then proceeds to test mode.
3. in the presence of any active zone the remote led "status" lights and the
corresponding of the 5 leds for the level of GsM radio signal lights as follows:
Zone - lights the led "" and the remote led "status".
Zone - lights the led "" and the remote led "status"
Zone 3 - lights the led "4" and the remote led "status"
Zone 4 - lights the led "8" and the remote led "status"
Zone 5 - lights the led "6" and the remote led "status"
4. With activated "tamper" (interruption) or fault (short circuit) for a zone, the
corresponding led flashes.
5. in the presence of "tamper" the indication for active zone goes off.
6. in the absence of an active zone the running lights continues.
7. signal "Gong" is generated for the zones for which it is configured.
8. this mode is released after turning off the power and removing the jumper
between terminals "Y" and "G".
Configuration parameters
. times for entering in any delay zone and exit time.
. duration of the turning on of the high current output (siren).
3. delay of transmission of signals for stopping and restoring the battery
charge.
4. GsM numbers - up to 6 pcs.
5. for each GsM number: options for sending sMs alarms, for sending sMs
for faults, for permits for turning on and off module in armed mode and for format of
the returned response (sMs or call).
6. names of each of the zones, which can be used in sMs. each description
can contain up to 3 characters.
7. type of each zone: turned off, delayed, instant, 4-hr., interior, hidden
switch.
When the zone is turned off, its condition has no effect on the station.