== Alarm Parameters:
Entry Delay [sec] [dec]:"ed"= 15 00 0 0 0 0
Exit Delay [sec] [dec]: "xd"= 40
Zones Type [hex]: "zt"= 01 02 02 02 03 05
00=Off, 01=Delay, 02=Moment, 03=24 hour, 04=Interior, 5=HK, Chime+16, 32
Bell Time [sec] [dec]: "bt"= 60
Zones Delay[x10ms][dec]:"zd"= 30 30 30 30 30 30
Zones Activity [hex]: "za"= 01 01 01 01 01 01
0=NC, 1=NO, 2=NCB, 3=NOB, 4=NCBT, 5=NOBT, 6=NCDT, 7=NODT, 8=NC+NO DT
Chime Delay [x10ms]: "cd"= 10
AC Trouble Delay [min]: "at"= 30
AC Restore Delay [min]: "ar"= 5
Zone 1 Description: "z1"= Zone 1 Alarm
Zone 2 Description: "z2"= Zone 2 Alarm
Zone 3 Description: "z3"= Zone 3 Alarm
Zone 4 Description: "z4"= Zone 4 Alarm
Zone 5 Description: "z5"= Zone 5 Alarm
Zone 6 Description: "z6"= Zone 6 Alarm
Factory Default: "fd"
Read RAM Data: "rd"
To Main Menu: "mm"
>
6. the duration of the signal "
Gong"/"Chime
" is in 0 ms. steps.
7.
Forced
allow arming of the panel if the zone is active.
8. at failure to press any key for about 0 seconds appears:
Timeout...
and the programming mode is terminated.
9. after entering from the main menu of
cp
the module sends:
== Codes Parameters:
Serial Number [hex]: "sn"= 12 34 56
ID Number [hex]: "id"= 03 07 07
Config Code [ASCII]: "cc"= homeal
Encryption Code: "ec"= FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
Alarm Codes Mode [dec]: "am"= 9
01=Hidden Key, 02=User Code, 04=RFID, 08=GSM, Summary
User & RFID Codes 1 "c1"= 01 2A 3B 4C 01 78 32 9F FF FF FF FF FF FF FF FF FF FF
FF FF FF FF FF FF FF FF FF FF FF FF FF FF