background image

6

 

in a GPrs communication mode: led "" lights in case of communication via 

GPrs to the monitoring center and goes off briefly during data transmission.

 

in order to reduce the current consumption, the 5 leds for level of GsM radio 

signal can be turned off by removing the jumper to them.

 

note: on the circuit boards designed to work over GPrs with monitoring cent-

er, the led "" instead of green is blue. in GPrs mode it has the following additional 

indications:

 

- does not glow: no GPrs connection to the server;

 

- flashes: there is a link to the server, but there is a discrepancy in the identi-

fication codes: serial number, id code of the module, encryption;

 

- Glows constantly: GPrs connection to the server is undamaged;

 

- shortly off: the module transmits data to the server.

Remote LED for the GSM module mode

 

- does not glow: the module is not turned on

 

- flashing: 64ms on / 800 ms off: has not detected a network

 

- flashing: 64ms on / 3000 ms off: has detected a network

 

- flashing: 64ms on / 300 ms off: GPrs communication

Green LED on the PCB

the green led lights in the presence of ac power.

Configuring

there are two ways to configure the control panel - via Pc and via sMs.

Configuring via PC

 

configuration is done via a Pc serial coM port, through Hiperterminal or other 

communications software with a special signal cable. if the computer does not have 

coM port, you can use the UsB port and adapter UsB/rs3. the procedure is as 

follows:

 

. to include the system to a personal computer it is necessary to connect the 

signal cable between the respective serial "com" port of the computer and commu-

nication connector "Uart" on the PcB. on the computer is started terminal software 

with speed 38400 bps, no flow control. the echo is better to be off.

 

. the signal cable converts the rs-3 or UsB interface of the Pc to Uart. 

the wires are as follows:

 

- power  V, coming from the module; for the UsB cable it is not nec-

essary

 

- tx of the module (Uart);

 

- rx of the module (Uart);

 

- a signal ground - from the antenna connector.

Summary of Contents for PC GSM 612

Page 1: ...PC GSM 612 HOME ALARM GUIDANCE FOR INSTALLERS...

Page 2: ...the codes 10 c GSM parameters 10 d GPRS parameters 11 e Measured voltage at the terminals of the different kinds of zones 11 6 Inclusion exclusion under arming 11 7 Armed mode 12 8 Announcement 13 9...

Page 3: ...n to turning on off at arming by telephone permission to send SMS in the failure restore of the AC power GSM number to check the validity and limits of a prepaid SIM card 4 Powerful output 12V 1A for...

Page 4: ...Warning The events of the twin zones are transmitted to the centre by num bers to which was added 10 for example the twin zone 3 will be displayed as a zone 13...

Page 5: ...rnal transformer Bt plus and minus of the battery Ld LED Status for indicating of operating mode connects between Ld and Aux 12V with a plus to the Aux Aux 12V power supply for external sensors two lu...

Page 6: ...chassis minus of the power supply Z5 Zone 5 balanced connects between Z5 and ground HK Zone 6 balanced connects between HK and ground Connecting of the zones is done in the following ways NC unbalanc...

Page 7: ...tion or fault short circuit for a zone the corresponding LED flashes 5 In the presence of Tamper the indication for active zone goes off 6 In the absence of an active zone the running lights continues...

Page 8: ...f the zones in a separate scheme 9 Activation time of each of the zones with step 10 ms 10 Permission for arming at active instant or delay zone bypass upon activa tion 11 Method of switching on and o...

Page 9: ...e 0 Off 1 Delay 2 Instantaneous 3 24 hours 4 Interior 5 Arming hidden switch Active state and balance measured voltages 0 NC unbalanced 0 5V 1 NO unbalanced 4 5V 2 NC balanced 2 9V 3 NO balanced 2 9V...

Page 10: ...nfiguration code homeal GSM parameters Notification GSM 1 GSM 2 GSM 3 GSM 4 GSM 5 GSM 6 SMS on alarm Yes Dial at alarm No Dial at inclusion exclusion under arming Yes Permission for inclusion exclu si...

Page 11: ...Alarm Alarm Both Tamper Trouble 0 NC unbalanced 0 5V 5V 1 NO unbalanced 5V 0 5V 2 NC balanced 2 9V 4 5V 0 5V 3 NO balanced 2 9V 0 5V 5V 4 NC bal with tamper 2 9V 4 3V 5V 0 5V 5 NO bal with tamper 4 3...

Page 12: ...rns off the system generates six squawks and the panel is not included in security 6 The zones status is monitored only at the time of inclusion of the hidden switch If the zone is activated or restor...

Page 13: ...4 Continuous monitoring of the battery voltage if for 30 minutes in all checking the voltage is 10 5V a message is sent for diluted battery LOW BATTERY TROU BLE ALARM and respectively if for 30 minute...

Page 14: ...The module sends an SMS to the specified number System ARMED zones A N N A N N AC Power On System disarmed zones N A N N N N AC Power Off wherein A means Active Active zone the zone is activated and N...

Page 15: ...shes two or three times quickly during a half second there was an alarm the panel is in alarm the siren is turned on Flashes once per second passes entry time or exit time Level 5 pcs green LEDs 1 2 4...

Page 16: ...rk Flashing 64ms ON 3000 ms off has detected a network Flashing 64ms ON 300 ms off GPRS communication Green LED on the PCB The green LED lights in the presence of AC power Configuring There are two wa...

Page 17: ...menu they are written in small letters Of each byte in command mode the module returns an echo 8 Alarm Parameters Codes Parameters and GSM Parameters are the three menus for programming 9 After the co...

Page 18: ...arm Zone 5 Description z5 Zone 5 Alarm Zone 6 Description z6 Zone 6 Alarm Factory Default fd Read RAM Data rd To Main Menu mm 16 The duration of the signal Gong Chime is in 10 ms steps 17 Forced allow...

Page 19: ...ters not just num bers 23 After entering from the main menu of gp the module sends GSM Parameters APN Address aa internet vivatel bg PDP Address pa 0 0 0 0 Server TCP IP 1 s1 192 168 1 51 Server Port...

Page 20: ...is very cumbersome it takes more than 30 seconds Better is the announcement by GSM for arisen events to be done via SMS 26 GSM Mode Options these are the options for the operating mode of GSM if GPRS...

Page 21: ...details the device responds with OK For example Serial Number serial number of the module 6 digits sn 77 77 77 the answer is 40 Command for reading rd After its submission the display shows RAM Data...

Page 22: ...ement of individu al commands does not matter important is just to begin with code and the correct configuration code and ends with go If at the end there is a number to which the module to send an SM...

Page 23: ...3 If must be entered a hexadecimal number compulsory is to be entered two characters even if the first is zero If the hexadecimal number contains a letter it must be small Latin a b c d e f When enter...

Page 24: ...ve state and for balance of the sensors see the figure Variants of connecting zones normally open or closed contact balanced or unbalanced with tamper or without tamper paired or single by default all...

Page 25: ...phone 10 Arm and disarm by configured method The LED Status should be lit at arming and go off on disarming 11 If at the time of arming with a secret switch there is an active zone disarm ing is not...