GPRS parameters
GPrs working mode:
GPrs, tcP/iP, UdP, encryption, sMs
GPrs id code tcP/iP:
03 77 77
GPrs id code UdP:
00 77 77
GPrs server :
3..33.
GPrs server :
3..33.
GPrs Port :
6086
GPrs Port :
6086
server timeout [x0 sec]:
35
Module timeout [x0 sec]:
5
encryption code:
ff ff …. ff
Периодичен Тест [h]:
6
UdP acknowledge interval [sec]:
60
Username:
Password:
aPn:
PdP:
0.0.0.0
config code:
homeal
serial number:
Measured voltage at the terminals of the different kinds of zones
code Zone
restore alarm alarm+ Both tamper trouble
0
nc, unbalanced
<0,5V
>5V
-
-
-
-
no, unbalanced
>5V
<0,5V -
-
-
-
nc, balanced
,9V
>4,5V -
-
-
<0,5V
3
no, balanced
,9V
<0,5V -
-
>5V
-
4
nc bal. with tamper
,9V
4,3V
-
-
>5V
<0,5V
5
no bal. with tamper
4,3V
,9V
-
-
>5V
<0,5V
6
nc, paired zones tamper ,8V
3,7V
,9V
4,3V >5V
<0,5V
7
no, paired zones tamper 4,3V
,9V
3,7V
,8V >5V
<0,5V
8
nc+no paired zones
with tamper
,9V
4,3V
,8V
3,7V >5V
<0,5V
Inclusion/exclusion under arming
.
inclusion/exclusion by a hidden switch
-
if there is the corresponding option
Hidden switch
enabled for this in
Alarm Codes Mode
;
-
will be sent a call to the authorized GsM numbers (after the exit time
expires) if there is an option enabled for this in
Armed Report
;