V4.0
200A Multi-Process Welder with LCD Display
8785115
Visit www.princessauto.com for more information
23
ASSEMBLY & INSTALLATION
Letter references in parenthesis (A) refer to the included Identification Key.
INPUT VOLTAGE
Type Input
Rated
Current
Output
Duty Cycle
X
I2
U2
ARC
120V
20A
10A/20.4V
~
70A/22.8V
40%
70A 18,5V
60%
57A 22.3V
100%
44A 21.7V
230V 36A
10A/20.4V
~
180A/27.2V
20% 180A 27.2V
60% 104A 24.1V
100%
80A 23.2V
MIG
120V
20A
40A/16V
~
90A/18.5V
40%
90A 18,5V
60% 73,5A 17,7V
100%
57A 16,8V
230V 36A
40A/16V
~
200A/24V
20% 200A
24 V
60% 115A 19.7V
100%
89A 18.5V
TIG
120V
20A
10A/10.4V
~
90A/13.6V
40%
90A 13.6V
60% 73.5A 12.9V
100%
57A 12.3V
230V
36A
10A/10.4V
~
180A/17.2V
20% 180A 17.2V
60% 104A 14.1V
100%
80A 13.2V
X = Duty cycle Percentage
I2 = Welding Current
U2 = Secondary Voltage with Welding Current I2
TORCH POLARITY
Placement of the dinse connector (I) determines the torch’s polarity.
Straight Polarity or Torch Negative (-).
Insert the dinse connector into the
negative output socket (H). The torch has negative polarity in this configuration.
Reverse Polarity or Torch Positive (+).
Insert the dinse connector into the
Positive Output Socket (G). The torch has positive polarity in this configuration.
Table 1