Installation - Page 12
2.7
Fit the Optional Vertical Balanced Flue
This Vertical Balanced Flue kit is only for use with the Ultra 2 Boiler and allows the flue to run vertically from the boiler,
terminating above either a flat or pitched roof.
The kit must be used with at least ONE, and up to THREE 1 metre flue extension kits, in conjunction with the horizontal
standard flue kit. The minimum flue length is 1.2 metres and the maximum permissible flue length is 3.25 metres.
To render the installation weatherproof, a storm collar and an adjustable flashing are recommended. The size of these
components should be to suit a 3 in. Twin Wall B vent flue system from:
Rite Vent
Armstrong Industrial Estate
Washington
Tyne & Wear. NE37 1LH
Tel: 0191 416 1150
Storm Collar - Ref. 156 Adjustable Flashing - Ref. 151
Minimum Flue length (dimension A) 1.2m
Length of Vertical Flue (dimension A)
Standard flue
750mm
One flue extension
1750mm
Two flue extensions
2750mm
Three flue extensions
3250mm
Terminal
Position
Min
Distance
A Directly below an openable
window or other opening
e.g. air brick
B Above roof level
C From adjacent wall
D From internal corner
E Below eaves or balcony
F From facing terminal
300 mm
300 mm
210 mm
230 mm
600 mm
1200 mm
Kit Contents
Description
Qty
Flue Terminal Cowl
1
Vertical flue adaptor ring
1
Sealing plate
1
Gasket
1
M4 x 16 Ig. hex. hd. screw
4
Support brackets
3
No.8 x 10 Ig. pozi hd. screw
12
Ceiling template
1
Summary of Contents for Ultra 2
Page 6: ...Installation Requirements Page 6 Fig 1 ...
Page 7: ...Installation Requirements Page 7 Fig 2 ...
Page 9: ...Installation Requirements Page 9 ...
Page 37: ...Routine Maintenance Page 37 ...
Page 51: ...7 Wiring Diagrams Page 51 ...
Page 52: ...Wiring Diagrams Page 52 Ultra 2Dv ...
Page 53: ...Wiring Diagrams Page 53 Ultra 2 ...
Page 54: ...54 Fault Finding Part No 405 0522 8 Fault Finding Guide Page 54 ...
Page 55: ...Part No 405 0522 Fault Finding 55 Fault Finding Guide Page 55 ...
Page 56: ...56 Fault Finding Part No 405 0522 Fault Finding Guide Page 56 ...
Page 57: ...Part No 405 0522 Fault Finding 57 Fault Finding Guide Page 57 ...