Data Definition:
<Count> runs from 0 to 336.
<ASCII number> values range from 0 to 255 (displayed in decimal base).
<Character> is the character that corresponds to the ASCII number; you may see a square or some other odd
character if the value is not displayable as a character.
The values represented:
Offset --- Usage Name
0
--- Track 1 decode status („0‟ = Good Read, „1‟ = Read Error)
1
--- Track 2 decode status („0‟ = Good Read, „1‟ = Read Error)
2 --- Track 3 decode status („0‟ = Good Read, „1‟ = Read Error)
3 --- Track 1 data length (Up to 110 Characters)
4 --- Track 2 data length (Up to 110 Characters)
5 --- Track 3 data length (Up to 110 Characters)
6 --- Card encoding type (Type 00 = ISO/ABA card Type 01 = AAMVA card Type 02 = CADL
Type 04= RFID)
7 - 116 --- Track 1 ASCII data (Mag card data or RFID UID number)
117 - 226 --- Track 2 ASCII data
227 - 336 --- Track 3 ASCII data