background image

18

GB

blue cable*

 

brown cable* 

blue cable* 

brown cable*

M1

M2

2

   Electric connections

  Connection of two servomotors.

 

 

The servomotors must be connected to the electrical box

  before the box is connected to the mains.

  Servomotor M1 must be mounted on the post of the leaf that opens first and closes last.

  

M2

 

       

M1

 

 

    

 

 

 

 

 

 

The servomotor M1 moves the right leaf that opens

 

 

 

 

 

 

as the first one and closes as the last one

Cables of servomotors:

Servomotor M1 must be always connected to terminals 11 and 12.
Servomotor M2 must be always connected to terminals 13 and 14.

* The colours of cables used may vary from these shown in the manual.
   Please take this into account during installation.

Summary of Contents for EASY WAY201

Page 1: ...DRIVE UNIT FOR SWING GATES EASY WAY 201 ...

Page 2: ...P 1x L 1x G 1x F 1x 2 SETS 8 SETS this lock screw is designed for gates mounted on steel posts 70 x 70 mm if the gate is to be mounted on steel posts 100 x 100 mm 8 sets of lock sc rews M8 x 120 mm should be obtained Depending on the model purchased a suitable connector should be added to the set ...

Page 3: ...nciples 5 Product description 6 Preparation for assembly 8 Installation 1 Automatic system installation 12 2 Electrical connections 17 3 Parameter setting 20 Operational use 26 Troubleshooting 28 Accessories 29 In the case of a solar energy supply 35 ...

Page 4: ...g facilities POLARGOS manufactures products for a large number of domestic and foreign customers Our aim is to supply products that meet the highest standards of workmanship and fulfill customers expectations as regards aesthetics and the dominant trends in the fence market Thank you for placing your confidence by choosing EASY WAY 201 Please read this instruction book thoroughly before installati...

Page 5: ...lly Before installation of the drive unit check if the driven part is in good technical condition properly balanced and if it opens and closes well Do not pass between the moving part and close fixed elements in view of the danger connected with the move ment of the driven parts during opening crushing cropping jamming Observe the gate during its movement All switches without interlock must be in ...

Page 6: ...2 453 Attachment A Working temperature Between 20 C and 60 C Thermal shield Yes Protection level IP 55 for electronic components IP 44 for drives Built in radio wave receiver Yes Remote controls Radio frequency 433 42 MHz Range of operational use 30 m Number of memory settings 16 Possible connections Orange light output Flashing 24 V 10 W Zone lighting output supplied terminals Max 500 W at 230 V ...

Page 7: ...00 kg H 2 00 m L 2 00 m Width of each leaf should be between 1 m and L Maximum opening angle for hinges fastened to the post side Dimensions in mm Opening limiter The motor stops automatically using its internal limiter To stop the gate earlier fix a limiter not included in the delivery on the ground to stop the leaves ...

Page 8: ...es without use of force The gate remains in a level position during the whole movement cycle It opens inwards to the garden Gate types only with frames made of metal Subject to observance of the dimensions specified on page 7 Inspection of posts The posts must be at least 70 mm wide Otherwise reconstruction may appear necessary to ensure proper corner embedment and fastening ...

Page 9: ...9 GB 6 5 7 5 10 5 13 10 Preparation for assembly Necessary tools ...

Page 10: ...If cables cannot be led underground between the posts use a cable bush that can withstand the weight of vehicles Mains supply To ensure operation of the gate opening mechanism connect a power supply of 230 V 50 Hz to it The electrical supply cable must be Designated for the gate opening mechanism only Protected by means of a fuse or a circuit breaker 10 A by means of a differential current switch ...

Page 11: ... L II I 8 SETS M8 x 120 mm H 8 SETS M8 x 85 mm H Preparation for assembly Preparation of connectors In case I use the lock screws M8 x 85 mm included in the delivery In case II where the metallic posts have dimensions 100 x 100 mm provide 8 sets of lock screws M8 x 120 mm ...

Page 12: ...P POST 70x70 30 30 I II 1 Automatic system installation Preparation of the gate 1 Level the gate leaves 2 Set position of the automatic system 3 Apply the prepared set to the previously leveled and closed gate The automatic system cannot rub against the gate fittings ...

Page 13: ... connectors P and L using a clamp Apply the automatic system to the gate and see which holes in the gate crossbar line up with the bean shaped holes in the connector V1 use two selected bean shaped holes 5 Attach the connector to the gate with screws Do not tighten all the way Some adjustment of the connector by gentle movement should be possible ...

Page 14: ...14 GB P H 1 Automatic system installation 6 Next attach the connector to the post with the gate closed The post must be drilled with a drill bit 10 5 7 Screw the connector to the post 10 5 ...

Page 15: ...to the suitably attached connectors 9 Check the position of the connector on the gate once again and adjust it if necessary 10 Remove the automatic system Choose one hole in the connector that does not interfere with a rail In its position drill the gate crossbar with a drill 6 5 Then ream the hole with a drill 7 5 from the street side Fit the locking screw M6 x 40 mm 7 5 6 5 ...

Page 16: ...g the leaf V1 or V2 using the screw C To use the unlocking element properly follow the assembly direction as shown in the diagram Do not mount the screw from below 12 Fix the yoke fastening the leaf V1 or V2 on the driving mandrel Attach the unlocking element D to the drive spindle to lock the mandrel 13 Repeat step 1 12 for the second gate leaf ...

Page 17: ...ld be mounted on the same side as the source of power supply Fixing the electrical box on the post 1 Place the box at the post preferably over one meter above the ground and use the template to drill installation holes 2 Put the electronic system in the box Press it slightly for proper location Fix the system using the mounting screws included in the delivery kit The box shall be mounted with the ...

Page 18: ...e mounted on the post of the leaf that opens first and closes last M2 M1 The servomotor M1 moves the right leaf that opens as the first one and closes as the last one Cables of servomotors Servomotor M1 must be always connected to terminals 11 and 12 Servomotor M2 must be always connected to terminals 13 and 14 The colours of cables used may vary from these shown in the manual Please take this int...

Page 19: ...these operations must be carried out with the power supply disconnected 1 Insert the cable into the gland 2 Connect the earth wire The earth wire green yellow will be needed for some accessories lighting 230 V Class I 3 Connect the live and the neutral Check if the wires are locked properly by pulling them It is necessary to always follow the rules regarding cable colours without variation Blue wi...

Page 20: ...ndicator DANGER is unlit Carry out the following operations Operation of remote controls The drive unit can be controlled by means of one or several remote controls The following operations must be repeated for each remote control to be programmed Two operating modes are available for the drive unit 9 Complete opening only Complete opening of 2 leaves by short or long pressing of the remotecontrol...

Page 21: ... again no later than within 10 seconds and hold it down until the indicator PROG starts flashing slowly the indicator DANGER will be alight during push button pressing 4 Release the push button it has been memorized At the end of the programming cycle only indicators PROG and ON OFF emit light however the electronic system is awaiting memorization of the path of the leaves Changing the operating m...

Page 22: ...bed in the section Programming of remote controls see information close by How to add remote controls with 3 push buttons Put the remote control in the place indicated on the housing 1 Press the push button UP or Down and hold it down until the indicator PROG starts flashing slowly the indicator DANGER will be alight during push button pressing 2 Release the push button the remote control has been...

Page 23: ...e remote control push button After several seconds the gate starts opening at low speed If the gate does not open properly check the servomotor cables as shown on page 18 2 After the gate is open press longer the remote control push button once again The gate closes one leaf after the other 3 Press the same push button once again The gate opens still at low speed 4 Press the push button for the la...

Page 24: ...e procedure of teaching of the movement path of leaves To this end restart programming of the remote control see page 22 Automatic mode adjustment Precautions To ensure the gate operation in automatic mode according to EN 12 453 it is necessary to install the following accessories that are available for the drive unit EASY WAY 201 photocell set description and cables see page 29 orange light descr...

Page 25: ...ivate closing by shorter or longer pressing the remote control push button again Both leaves close almost simultaneously Indicator AUTO emits light continuously The automatic mode is now active Switchover from automatic mode to sequential mode To return to sequential mode indicator AUTO is lit Put the remote control in the place indicated on the housing Press the transmitter push button until the ...

Page 26: ... in automatic mode In automatic mode pressing of the remote control push button results in the gate opening Closing occurs automatically after the period of time preset by the user You can stop the gate in the open position by short pressing of the remote control push button within the specified time Repeated pressing of the remote control push button results in the gate closing Operation of remot...

Page 27: ... control If a vehicle is equipped with air conditioning and metalized windscreen aim the remote the control at the black bar found on the windscreen or at the side window Engagement disengagement of the servomotor For safety reasons these operations must be carried out after disconnecting the power supply Even in the case of a power cut restoration of power supply can occur at any moment 1 In case...

Page 28: ...OFF is flashing quickly Servomotor is overheating wait for it to cool down Short circuit at the output s of the drive unit s contact the Service Department Servomotors M1 and M2 are not activated or the direction of their operation is not correct Check the connection to the electricity supply Check the extender between the two servomotors Check the servomotor cables if necessary exchange them see ...

Page 29: ... conductors locate the receiving photocell on the post where the drive unit equipped with the electronic system is placed Before the connection of photocells remove the conductor jumper that is installed between the electronic module terminals 3 and 4 Wiring diagram for the photocell set In case of a solar energy supply see page 35 To ensure better operation of the photocells fit them with a shiel...

Page 30: ...it directly Note Do not place the battery cable above a power supply source Operating time 10 cycles in continuous mode or 24 hours if the gate is in good technical condition Optimum charging time for the battery before use 48 hours Battery life 3 years To ensure optimum battery life disconnect the power supply from the gate three times a year and run several cycles with battery operated drive uni...

Page 31: ...31 GB Accessories Description and connections Key switch Intercom Accessories incompatible with solar energy supply ...

Page 32: ...GB T1 C1 R1 V R3 T2 C2 R2 T3 C3 H P2 M P1 H E V T1 C1 R1 V R3 T2 C2 R2 T3 C3 H P2 M P1 H E V Accessories Description and connections Cable panel with code Accessories incompatible with solar energy supply ...

Page 33: ...33 GB Accessories Description and connections Wireless wall switch Radio panel with code Remote control with 2 push butt Remote control with 4 push buttons ...

Page 34: ...ections External antenna An external antenna having a wider range can replace the wire antenna Place it on top of the post and check if it is exposed Connection to the electronic module conductor core to terminal 1 stranded aerial wire to the terminal 2 ...

Page 35: ...ing programming and the drive unit operation remain the same as for a power supply of 230 V Connection to a solar system supply 1 Insert the cable into the gland of the electric box of the drive unit 2 Connect the supply cable from the solar power system to the terminal of the battery 3 Clamp the gland Check if the wire is connected properly by pulling it ...

Page 36: ...36 GB RX TX 1 2 1 2 3 5 Accessories Photocells Wiring diagram for the photocell set Lamp for gate zone illumination 24V 25W ...

Page 37: ...37 GB ...

Page 38: ...38 GB ...

Page 39: ...39 GB ...

Page 40: ...ul Deptak 17 04 956 Warszawa tel 48 022 872 00 91 93 fax 48 022 612 68 60 serwis polargos pl www polargos eu ...

Reviews: