6 Technical Data
Plugreen Solar micro-inverter - AC Operating Parameters
Parameter/Model
Unit
Unit
Min
Min
Typical
Typical
Max
Max
PGM200/230/260
PGM200/230/260
200/230/260
PGM200/230/260
Output power factor
Maximum AC output Power (-40 to +65 Deg C)
Nominal AC output voltage range
Maximum AC output current
Nominal AC output frequency range
Extended AC output frequency range
High AC Voltage trip limit accuracy
Low AC Voltage trip limit accuracy
Frequency trip limit accuracy
W
Vrms
A
Hz
Hz
%
%
Hz
0.95
211
49.4
49.2
2.5
4
±0.1
0.99
230
.85/1/1.1
50
60
1
264
50.41
50.6
Miscellaneous Operating Parameters
Peak inverter efficiency
CEC weighted efficiency
Nominal MPP tracking efficiency
Total Harmonic Distortion
Operating temperature range
Storage temperature range
%
%
%
%
Deg C
Deg C
- 40
- 40
95
92
>99
5
+ 65
+ 65
Plug Green Micro Inverter Operating Parameters
Dimensions
Weight
Enclosure environmental rating
Cooling
Communication
Standard warranty term
Compliance applicable*
160X138X32mm
1.6Kgs
IP65/NEMA6
Convection
Power Line
15 Years
UL, CE, VDE
11
Copyright Plugreen Corporation. 2011 1-00001 REV 1
Note: Specifications are subjected change without notice. *Certifications pending