56
ULTRAPLEX 40X OPERATION MANUAL
12.2 PC Compatibles: Existing Installations
Symptoms
Additional Symptom
• Invalid drive specification
• Interface board driver fails to
• No device found
recognize the CD-ROM drive
• Drive not responding
Possible Causes and Solutions
Drive Is Not On
If you have an UltraPleX external drive, check that its front-panel power switch
is ON. If the drive is the UltraPleX internal model, ensure the power cord from
your computer’s power supply is plugged firmly into the drive power
connector. Power is applied correctly if one of the front panel LEDs are on.
Bad Connection Between the CD-ROM Drive and the SCSI Interface Board
Inspect the cable, drive, and interface board for recessed, broken, or bent pins.
If a ribbon cable is used, inspect for any signs of distress, such as kinking.
Ensure the red stripe side of the ribbon cable plugs into Pin 1 on both the drive
and the interface board.
Improper SCSI Bus Termination
Ensure that only the peripheral at the end of the internal SCSI cable and/or the
last peripheral in a daisy chain of external devices is terminated, see Chapter 7.
Some peripherals have a setting marked “Termination Power” instead of
“Terminator.” Ensure that termination power switches are set correctly.
Symptom
Additional Symptom
• CDR101—Not Ready
CD-ROM drive responds to directory
Reading Drive [X]
(DIR) command but cannot run a
program
Possible Causes and Solutions
Bad Connection Between the CD-ROM Drive and the SCSI Interface Board
Inspect the cable, drive, and interface board for recessed, broken, or bent pins.
If a ribbon cable is used, inspect for any signs of distress, such as kinking.
CHAPTER 12 — Troubleshooting
Summary of Contents for PX-40TSe
Page 93: ......