![Piusi CUBE B.SMART Installation, Use And Maintenance Manual Download Page 26](http://html.mh-extra.com/html/piusi/cube-b-smart/cube-b-smart_installation-use-and-maintenance-manual_1560342026.webp)
Installation, use and maintenance
M0546
26
/60
NOTE
The maximum current absorbed by the 230 V motor is 4.2 A
MAIN AC/DC POWER INPUT
CN9
WE P:7.62
F/+
N/-
1
2
3
earthing
-PE- (yellow/green)
neutral
-N-
(blue)
phase
-L-
(brown)
3
SIGNALS
connector:
Output 24 V dc and 25 mA, pulser, level 1 and 2 contact.
Tighten the screws on the top of the 8-hole terminal for: level 1 contact,
level 2 contact
GND
GND
GND
GND
GND
GND
24 V dc 25 mA
power supply
output
level 1
contact
level 2
contact
24 V dc 25 mA
power supply
output
level 1
contact
level 2
contact
4
Closing the
rear cover of
the controller
Replace the cover and tighten the 7 screws
5
Closing CUBE
Tighten the 2 side screws