POWER INPUT
230 V ac at 50 Hz.
MOTOR OUTPUT
230 V ac at 50 Hz
level 1
contact
level 2
contact
pulser
input
MOTOR
Once the cover has been opened, the electronic board and its connectors are accessed:
1
3
POWER SUPPLY INPUT
230 V ac at 50 Hz.
The line must be disconnected by an
electrical panel or by a plug-socket
Connector for:
level 1 and 2 contact,
GND and 24 V dc and
25 mA power supply
output
IN DETAIL:
1
Power supply
cable:
Insert the grounding wire (yellow/green sheath) into the central hole of
the terminal, then phase and neutral respectively on the right and left and
tighten the wire fixing screws.
Voltage values:
The electronic controller must be supplied with voltages and frequencies
compatible with the motor to be driven:
If the motor is 230 V ac at 50 Hz, the controller must be supplied at the
same voltage and frequency (220 V ac – 240 V ac at 50 Hz)
IMPORTANT
the CABLE CROSS-SECTION must be chosen according to the electrical
current absorbed by the motor, which is the device in which almost all the
current flows.