Installation, use and maintenance
M0546
36
/60
17
FLOW METER CALIBRATION
Before you can use the
CUBE B.SMART
, it is advisable that you check the
METERING ACCURACY.
To do so, proceed as follows:
• Enter a previously enabled USER PIN
• Dispense in a calibrated container
• Compare the quantity of diesel delivered with a calibrated container.
IMPORTANT
For a correct on accuracy it is essential to observe the following indications:
• Use a precision sample vessel with a graduated scale with capacity
indication of not less than 20 litres.
• Before checking, be sure to remove all air from the system, dispensing
until a full and regular flow is obtained.
• Continuously dispense at the maximum flow rate of CUBE B.SMART
• Stop the flow by quickly closing the dispensing nozzle.
• Reach the graduated area of the sample vessel avoiding prolonged low
flow rate deliveries, rather making short dispensings at maximum flow rate.
• Compare the indication provided by the container with the indication
provided by CUBE B.SMART, after waiting for any foam to disappear.
If the accuracy is NOT satisfactory, proceed with a CALIBRATION OF THE
FLOW METER as indicated in the specific manual.
IMPORTANT
Differences of up to 1/10 litre on 20-litre dispensings are within the
guaranteed accuracy of +/- 0.5%
IMPORTANT
For dispensings of 2 litres or less, the manufacturer does not guarantee
the same metering accuracy.
18
DAILY USE
All CUBE B.SMART models guarantee restricted access only to authorized
users. The SYSTEM recognizes the User’s authorization through two
alternative systems:
- REGISTRATION OF THE USER IN THE B.SMART APP
- Insertion of an electronic key
IMPORTANT
All AUTHORIZED USERS must be properly trained and be aware of at
least what is described in this chapter.
The configurability of the B.SMART system allows the User to ENTER
additional optional data (vehicle number plate, mileage, quantity to be
dispensed). See DIGITAL APP manual FOR ALL DETAILS. If these options
are not set, B.SMART recognizes the authorized USER and immediately
enables the pump, allowing the dispensing.
IMPORTANT
Enabling does not result in the immediate start of the pump; the pump is
controlled by a switch (located in the nozzle housing) operated by the user.
The pump starts (if previously enabled) as soon as the control lever is in the
ON position, while it switches off as soon as the control lever is in the OFF
position. No further manual action is necessary to start or stop the pump.
Summary of Contents for CUBE B.SMART
Page 1: ...CUBE Bulletin M0546 EN_01 Installation use and maintenance EN ...
Page 2: ...Installation use and maintenance M0546 2 60 Bulletin M0546 ENGLISH ...
Page 56: ...Installation use and maintenance M0546 56 60 24 EXPLODED VIEWS ...
Page 58: ...Installation use and maintenance M0546 58 60 note ...
Page 59: ......