7
Selection Buttons and Indicator Lights
Press these buttons to step through the feeders/options that are available on your
machine.
Depending on your model configuration, some indicator lights and associated
feeders may be inoperable. i.e. if your model doesn’t have a second sheet feeder,
the indicators associated with this feeder will not light – this is normal.
A green indicator shows that a feeder or function is selected for use.
A red indicator shows that you selected an invalid (impossible) combination of
functions. Simply correct the error in selection and the indicator(s) will change
back to green.
An unlit indicator means that the feeder or function is turned OFF.
Trial Piece
After a job has been setup using the control panel, a trial piece must be run. If
you press
Start before running a trial piece, the display will prompt you to run a
trial piece first.
Press this button to run one fully collated piece as programmed via the control
panel. The envelope will not seal regardless of whether the system has been told
to seal or not. This allows you to inspect the processed job to make sure that
everything is inserted correctly and that the address appears in the window. The
trial piece also allows the system to calibrate itself and set its double detect
feature, if selected.
IMPORTANT: Running the trial piece is essential and must be done prior to a
start every time a new batch of material is used. This allows the system to re-
calibrate in case different batches of material vary slightly.
Start
Press to begin automatic operation.
Stop
Press to stop automatic operation at the end of the next cycle.
IMPORTANT – SLEEP MODE
After 10 minutes of inactivity the system will enter a power saving ‘sleep mode’
and displays Powersave On. Press any button to wake the machine up. The
machine remembers the last job setup.
4
5
6
7
Introduction