L20-195  R7

 WARNING PAGE

TO THE PURCHASER, OWNER AND STORE MANAGER 

Please review these warnings prior to posting them in a prominent location for reference.

TO THE PURCHASER 

Post in a prominent location the instructions to be followed in the 
event that an operator smells gas. Obtain this information from your 
local gas supplier. 

FOR YOUR PROTECTION 

DO NOT store or use gasoline or other flammable vapors and liquids 
in the vicinity of this or any other appliance. 
Do not spray aerosols in the vicinity of this appliance when it is in 
operation. 

WARNING 

Improper installation, operation, alteration, adjustments, service or 
maintenance can cause property damage, injury or death. Read the 
installation, operating and maintenance instructions thoroughly before 
installing, operation, servicing this appliance. 

WARNING 

Installation, maintenance and repairs should be performed by a Pitco 
Authorized Service and Parts (ASAP) company technician or other 
qualified personnel.  Installation, maintenance or repairs by an 
unauthorized and unqualified personnel will void the warranty. 

WARNING 

Installation and all connections must be made according to local 
codes in force. In the absence of local codes in North America, the 
installation must conform with the National Fuel Gas Code, ANSI 
Z223.1/NFPA 54 or the Natural Gas and Propane Installation Code 
CSA B149.1 as applicable. In Australia, the appliance must installed 
in compliance with AS/NZS 5601. 

WARNING 

During the warranty period if a customer elects to use a non-original 
part or modifies an original part purchased from Pitco and/or its 
Authorized Service and Parts (ASAP) companies, this warranty will be 
void.  In addition, Pitco and its affiliates will not be liable for any 
claims, damages or expenses incurred by the customer which arises 
directly or indirectly, in whole or in part, due to the installation of any 
modified part and/or received from an unauthorized service center. 

WARNING 

This appliance, when installed, must be electrically grounded in 
accordance with local codes, or in the absence of local codes, with the 
National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical 
Code, CSA C22.2, as applicable 

WARNING 

Adequate means must be provided to LIMIT the movement or this 
appliance without depending on the gas or electrical cord connection.  
Single appliances equipped with legs must be stabilized by installing 
anchor straps.  All appliances equipped with casters must be 
stabilized by installing restraining chains. 

WARNING 

DO NOT alter or remove structural material on the appliance to 
accommodate placement under a ventilation hood. 

WARNING 

If the appliance is equipped with a power cord and it is damaged, it 
must be replaced by a Pitco Authorized Service and Parts (ASAP) 
company technician, or a similarly qualified person in order to avoid a 
hazard. 

WARNING 

The power supply must be disconnected before servicing, maintaining 
or cleaning this appliance. 

WARNING 

The appliance is NOT jet stream approved.  DO NOT clean the 
appliance with a water jet. 

WARNING 

DO NOT attempt to move this appliance or transfer hot liquids from 
one container to another when the unit is at operating temperature or 
filled with hot liquids. Serious personal injury could result if skin 
comes in contact with the hot surfaces or liquids. 

WARNING 

DO NOT use an open flame to check for gas leaks! 

WARNING 

DO NOT sit or stand on this appliance. The appliance’s front panel, 
tank, splash back, tank cover, work shelf, drain board is not a step.  
Serious injury could result from slipping, falling or contact with hot 
liquids. 

WARNING 

NEVER use the appliance as a step for cleaning or accessing the 
ventilation hood.  Serious injury could result from slips, trips or from 
contacting hot liquids. 

WARNING 

The oil/shortening level should NOT fall below the minimum indicated 
level line at any time.  The use of old shortening can be dangerous as 
it will have a reduced flash point and be more prone to surge boiling. 

WARNING 

The contents of the crumb catch and/or filter pan of any filter system 
must be emptied into a fireproof container at the end of the frying 
operation each day.  Some food particles can spontaneously combust 
into flames if left soaking in certain oil/shortening materials. 

WARNING 

Completely shut the appliance down when shortening/oil is being 
drained from the appliance. This will prevent the appliance from 
heating up during the draining and filling process.  Serious injury can 
occur.

WARNING 

This appliance is intended for indoor use only. 

WARNING 

DO NOT operate appliance unless all panels and access covers are 
attached correctly. 

WARNING 

It is recommended that this appliance be inspected by a qualified 
service technician for proper performance and operation on a yearly 
basis.

WARNING 

There is an open flame inside this appliance. The unit may get hot 
enough to set nearby materials on fire. Keep the area around the 
appliance free from combustibles. 

WARNING 

DO NOT supply the appliance with a gas that is not indicated on the 
data plate. If you need to convert the appliance to another type of fuel, 
contact your dealer. 

WARNING 

If gas flow to appliance is interrupted, or pilots extinguish, wait 5 
minutes before attempting to relight the pilot to allow any residual gas 
in appliance to dissipate. 

WARNING 

Ensure that the appliance can get enough air to keep the flame 
burning correctly. If the flame is starved for air, it can give off a 
dangerous carbon monoxide gas. Carbon monoxide is a clear 
odorless gas that can cause suffocation. 

WARNING 

Never add oil to the appliance when it is at operating temperature.  
Splashing hot oil can cause severe injuries. 

WARNING 

Never add water to hot oil.  Violent boiling can occur causing severe 
injury. 

WARNING 

This appliance is intended for professional use only and should be 
operated by fully trained and qualified personnel. 

WARNING 

To avoid splashing of hot liquid when installed, this fryer must be 
restrained either by the manner of installation, or with adequate ties to 
prevent tipping. 

WARNING 

An appliance equipped with casters and a flexible gas line must be 
connected to the gas supply with a quick disconnect device. In North 
America, gas appliances equipped with casters must be installed with 
connectors that comply with the Standard for Connectors for Movable 
Gas Appliances, ANSI Z21.69.CSA 6.16 Latest Edition. This connection 
should include a quick disconnect device that complies with the Standard 
for Quick Disconnect Devices for Use With Gas Fuel ANSI Z221.41.CSA 
6.9 Latest Edition. In Australia, an appliance equipped with casters and a 
flexible gas line must be connected to the gas supply with a quick 
disconnect device that complies with AS 4627.  The hose must comply 
with AS/NZS 1869 and be class B or D and have a restraining cable. The 
restraining cable must not exceed 80% of the length of the flexible gas 
line.

 ENGLISH

Summary of Contents for Frialator SG 14

Page 1: ...and retain this manual for the life of the equipment Model ______________________________________ Serial ______________________________________ Date Purchased ________________________________ Installa...

Page 2: ...k for gas leaks WARNING DO NOT sit or stand on this appliance The appliance s front panel tank splash back tank cover work shelf drain board is not a step Serious injury could result from slipping fal...

Page 3: ...as Connection 5 Fuel Supply Line Leak and Pressure Testing 5 Electric Connection 5 Ventilation and Fire Safety Systems 5 Gas Line Requirements 5 Lighting Instructions 6 Initial Cleaning 6 Daily Cleani...

Page 4: ...en all four legs casters are mounted stand the unit up being careful not to put too much weight on any one leg caster Adjust the height and level the fryer by adjusting the leveling devices on the leg...

Page 5: ...ANSI NFPA 70 to install the service In Canada refer to CSA Standard C22 1 and local codes Wiring diagrams are provided inside the fryer control box Ventilation and Fire Safety Systems Your new fryer...

Page 6: ...it f When the tank has cooled rinse it thoroughly with cool water Continue to rinse the tank until the cleaner has been rinsed thoroughly from the tank g Using a clean dry cloth wipe out all of the wa...

Page 7: ...the calibration check detailed below you will need a digital thermometer a Place the tip of the thermometer in the oil approximately 1 above the temperature sensors b Set the thermostat at 325 F and...

Page 8: ...thermostat until the shortening is liquidized enough to cover the heat tubes This will protect the tank and components from damage and extend the life of the oil Fryer Shut Down There are two shutdow...

Page 9: ...OF FIRE EXTINGUISHERS AND DETECTION EQUIPMENT CO2 ANSI UL 154 ANSI NFPA 12 DRY CHEMICAL ANSI UL 299 ANSI NFPA 17 WATER ANSI UL 626 ANSI NFPA 13 FOAM ANSI UL 8 ANSI NFPA 11 SPRINKLERS ANSI UL 199 ANSI...

Page 10: ...10 L20 195 R7 THIS PAGE WAS LEFT BLANK INTENTIONALLY ENGLISH...

Page 11: ...om 8 00 a m 5 00 p m Eastern Standard Time Monday through Friday at 603 225 6684 World Wide In the event of problems with or questions about you equipment please contact the Pitco Frialator Authorized...

Page 12: ...Please complete this information and retain this manual for the life of the equipment Model ______________________________________ Serial ______________________________________ Date Purchased _______...

Page 13: ...la cuve ni la plaque anti claboussures ni le couvercle de la cuve ni le plan de travail de l appareil ni la plaque collectrice ne sont des marchepieds Des blessures graves risquent d tre caus es par u...

Page 14: ...onales fournies avec la friteuse Chaque pied roulettes doit tre fix avec des vis de fixation de 1 4 20 x 5 8 de po c Fixez les vis partir de l int rieur de la friteuse en pla ant l crou l ext rieur Le...

Page 15: ...a taille du tuyau de gaz peut tre d termin e par la compagnie du gaz de votre localit en se r f rant au Code national d installation des appareils gaz paragraphe C tableau C 4 gaz naturel et tableau C...

Page 16: ...tez vous au Code lectrique national des tats Unis NEC et aux normes ANSI NFPA pour l installation lectrique Au Canada reportez vous la norme CSA C22 1 et la r glementation de votre localit Les diagram...

Page 17: ...on de la machine Nettoyez la machine en suivant les indications suivantes a Remplissez la friteuse avec de l eau b R glez la commande de gaz de la friteuse sur ON Laissez la friteuse chauffer l eau ju...

Page 18: ...s l eau chaude pendant 15 minutes g Utilisez la brosse nettoyer pour friteuse frottez l int rieur de la friteuse afin de retirer le rev tement protecteur h Apr s avoir nettoy la friteuse r glez la com...

Page 19: ...purge est compl tement ferm b Remplissez la friteuse d huile jusqu au rep re du niveau d huile Oil Level indiqu au dos de la cuve Remplir la Friteuse de Mati re Grasse en Bloc a Assurez vous que le ro...

Page 20: ...Y EQUIPO DE DETECTCION DE INCENDIOS CO2 ANSI UL 154 ANSI NFPA 12 EXTINCTEUR POUDRE ANSI UL 299 ANSI NFPA 17 EXTINCTEUR EAU ANSI UL 626 ANSI NFPA 13 EXTINCTEUR MOUSSE ANSI UL 8 ANSI NFPA 11 ARROSEURS...

Page 21: ...nt votre commande de 8 00 heures 17 00 heures heure normale de l Est des tats Unis du lundi au vendredi 603 225 6684 Veuillez contacter votre repr sentant agr Pitco Frialator si vous avez des probl me...

Page 22: ...L IMPORTANT FOR FUTURE REFERENCE Please complete this information and retain this manual for the life of the equipment Model ______________________________________ Serial _____________________________...

Page 23: ...salpicadero la cubierta del tanque el estante de trabajo ni el drenaje del equipo Es posible que sufra lesiones graves por resbalarse caerse o entrar en contacto con l quidos calientes ADVERTENCIA NUN...

Page 24: ...ldanas si es el caso con los pernos de cabeza hexagonal que se suministran conelfreidor Cada pata roldana requiere 4 pernos de 1 4 20 x 5 8 c Monte los pernos desde el interior del freidor con la tuer...

Page 25: ...Disconnect Devices for Use with Gas Fuel ANSI Z223 1 Cuando se instale el artefacto para desconexi n r pida tambi n deben instalarse un sistema para limitar el movimiento del freidor Este sistema deb...

Page 26: ...permanentes Los da os causados por corrientes descendentes de aire no est n cubiertos bajo la garant a del equipo NUNCA permita la obstrucci n del flujo de combustible o el de la ventilaci n de salida...

Page 27: ...n de gas a la posici n PILOT y permita que el freidor se caliente por 15 minutos AVISO Nodejeelfreidordesatendidodurantelalimpieza Nuncadejequeelniveldeaguadesciendapor debajo de la marca Min Level e...

Page 28: ...ado Drene el agua en un recipiente adecuado para agua caliente y vi rtala al desag e i Cuando el tanque se haya enfriado enju guelo completamente con agua fr a Contin e enjuagando el tanque hasta que...

Page 29: ...e hasta que los quemadores se prendan a una temperatura de 325 F 163 C Vuelva a colocar la perilla y permita que el freidor realice su ciclo de 4 a 6 veces Verifique la temperatura del term metro cont...

Page 30: ...mostato a la posici n OFF apagado Gire la v lvula de gas a la posici n PILOT El freidor est ahora en Standby y puede mantenerse en estas condiciones por cortos per odos de tiempo NUNCA deje el freidor...

Page 31: ...EQUIPO DE DETECTCION DE INCENDIOS CO2 ANSI UL 154 ANSI NFPA 12 SUBSTANCIA QUIMICA ANSI UL 299 ANSI NFPA 17 AGUA ANSI UL 626 ANSI NFPA 13 ESPUMA ANSI UL 8 ANSI NFPA 11 ROCIADORES ANSI UL 199 ANSI NFPA...

Page 32: ...a las 5 de la tarde Tiempo Est ndar del Este de lunes a viernes 603 225 6684 En caso de problemas o preguntas relativas a su equipo por favor comun quese con el repre sentante de Partes y Servicio Au...