background image

6

L20-195  R7

 Lighting Instructions

 

a. Fill tank before lighting.

 

b. Turn combination gas valve knob to “PILOT” position.

 

c. Depress valve knob and light pilot. With pilot burning, hold knob depressed for 60 seconds.

 

d. Release knob, pilot should remain lit.

 

e. DO NOT TURN COMBINATION GAS VALVE KNOB TO THE “ON” POSITION UNTIL VESSEL IS FULL OF

 

WATER OR SHORTENING. TURNING THE KNOB TO “ON” WITH TANK EMPTY WILL DAMAGE THE

 

TANK OR COMPONENTS AND VOID WARRANTY.

 

f. Relighting - wait 5 minutes before attempting to relight the pilot to allow for any gas in the fryer to dissipate.

 Initial Cleaning

When the fryer is shipped, many of its parts are covered with a thin coat of oil for protection. Before the fryer is ready for
cooking it must be cleaned. This will remove the oil coating and any foreign matter that may have accumulated during 
storage and shipment. Perform the cleaning as described below.
 

a. Fill the tank with water.

 

b. Turn the fryer gas valve knob to the “ON” position. Allow the fryer to bring the water to a low boil and add one

 

packet of Pitco fryer cleaner or a mild, low sudsing detergent and allow water to continue to boil for a minute,

 

making sure water does not boil over.

 

c. Turn the gas valve knob to the “PILOT” position and allow fryer to soak with the hot water for 15 minutes.

NOTICE

Do not leave the fryer unattended during cleaning. Never let the water level go below the "Min

Level" mark on the back of the tank.

 

d. Using the fryer cleaning brush, scrub the inside of the fryer to remove protective coating.

 

e. When cleaning is complete, turn the gas valve knob to the “OFF” position and drain the water into a container

 

suitable for hot water and dispose of it.

 

f. When the tank has cooled, rinse it thoroughly with cool water. Continue to rinse the tank until the cleaner has

 

been rinsed, thoroughly from the tank.

 

g. Using a clean dry cloth, wipe out all of the water. Be very thorough removing the water, because any residual

 

water will cause hot oil to splatter out of the fryer. Close the drain valve and remove container.

CAUTION

Mild steel tanks must be wiped down/coated with oil to keep the tank from rusting.

 

h. Now that the tank is clean, you are ready to fi ll and operate the fryer. Refer to instructions on adding shortening

 

to the fryer.

 Daily Cleaning

Should be performed to maintain peak operation and appearance.
 

a. Wipe up any shortening that spills onto the exterior of the fryer. This should be done with a clean soft cloth

 

while the oil is still warm.

 

b. Use warm water with a mild detergent to clean surfaces. Be careful not to get water in the shortening and to

 

remove any detergent from the fry tank.

 

c. Use a nonabrasive scouring powder or pad to clean stains if necessary.

 

d. Perform the weekly boil out cleaning of your fryer described below.

 Weekly Fryer Cleaning

This cleaning should include a complete draining of the fryer and a boil out.
 

a. You will need a container large enough to hold 1 1/2 times the oil in one tank. This container should also be

 

able to withstand 400“ F oil temperatures.

 

b. Shut fryer gas system OFF completely before performing procedures to ensure unit does not come on during

 

any part of the cleaning operation.

 

c. Drain the oil from the fryer and discard or save for reuse. Remove tube rack/mesh tube screens and remove  

 

any large debris from the bottom of the fry tank. Once clean, return tube rack/mesh screens to the fry tank.  

 

Close the drain valve and fi ll the fry tank with water and non caustic detergent.

 

d. Relight gas system pilot, following the lighting instructions.

 ENGLISH

Summary of Contents for Frialator SG 14

Page 1: ...and retain this manual for the life of the equipment Model ______________________________________ Serial ______________________________________ Date Purchased ________________________________ Installa...

Page 2: ...k for gas leaks WARNING DO NOT sit or stand on this appliance The appliance s front panel tank splash back tank cover work shelf drain board is not a step Serious injury could result from slipping fal...

Page 3: ...as Connection 5 Fuel Supply Line Leak and Pressure Testing 5 Electric Connection 5 Ventilation and Fire Safety Systems 5 Gas Line Requirements 5 Lighting Instructions 6 Initial Cleaning 6 Daily Cleani...

Page 4: ...en all four legs casters are mounted stand the unit up being careful not to put too much weight on any one leg caster Adjust the height and level the fryer by adjusting the leveling devices on the leg...

Page 5: ...ANSI NFPA 70 to install the service In Canada refer to CSA Standard C22 1 and local codes Wiring diagrams are provided inside the fryer control box Ventilation and Fire Safety Systems Your new fryer...

Page 6: ...it f When the tank has cooled rinse it thoroughly with cool water Continue to rinse the tank until the cleaner has been rinsed thoroughly from the tank g Using a clean dry cloth wipe out all of the wa...

Page 7: ...the calibration check detailed below you will need a digital thermometer a Place the tip of the thermometer in the oil approximately 1 above the temperature sensors b Set the thermostat at 325 F and...

Page 8: ...thermostat until the shortening is liquidized enough to cover the heat tubes This will protect the tank and components from damage and extend the life of the oil Fryer Shut Down There are two shutdow...

Page 9: ...OF FIRE EXTINGUISHERS AND DETECTION EQUIPMENT CO2 ANSI UL 154 ANSI NFPA 12 DRY CHEMICAL ANSI UL 299 ANSI NFPA 17 WATER ANSI UL 626 ANSI NFPA 13 FOAM ANSI UL 8 ANSI NFPA 11 SPRINKLERS ANSI UL 199 ANSI...

Page 10: ...10 L20 195 R7 THIS PAGE WAS LEFT BLANK INTENTIONALLY ENGLISH...

Page 11: ...om 8 00 a m 5 00 p m Eastern Standard Time Monday through Friday at 603 225 6684 World Wide In the event of problems with or questions about you equipment please contact the Pitco Frialator Authorized...

Page 12: ...Please complete this information and retain this manual for the life of the equipment Model ______________________________________ Serial ______________________________________ Date Purchased _______...

Page 13: ...la cuve ni la plaque anti claboussures ni le couvercle de la cuve ni le plan de travail de l appareil ni la plaque collectrice ne sont des marchepieds Des blessures graves risquent d tre caus es par u...

Page 14: ...onales fournies avec la friteuse Chaque pied roulettes doit tre fix avec des vis de fixation de 1 4 20 x 5 8 de po c Fixez les vis partir de l int rieur de la friteuse en pla ant l crou l ext rieur Le...

Page 15: ...a taille du tuyau de gaz peut tre d termin e par la compagnie du gaz de votre localit en se r f rant au Code national d installation des appareils gaz paragraphe C tableau C 4 gaz naturel et tableau C...

Page 16: ...tez vous au Code lectrique national des tats Unis NEC et aux normes ANSI NFPA pour l installation lectrique Au Canada reportez vous la norme CSA C22 1 et la r glementation de votre localit Les diagram...

Page 17: ...on de la machine Nettoyez la machine en suivant les indications suivantes a Remplissez la friteuse avec de l eau b R glez la commande de gaz de la friteuse sur ON Laissez la friteuse chauffer l eau ju...

Page 18: ...s l eau chaude pendant 15 minutes g Utilisez la brosse nettoyer pour friteuse frottez l int rieur de la friteuse afin de retirer le rev tement protecteur h Apr s avoir nettoy la friteuse r glez la com...

Page 19: ...purge est compl tement ferm b Remplissez la friteuse d huile jusqu au rep re du niveau d huile Oil Level indiqu au dos de la cuve Remplir la Friteuse de Mati re Grasse en Bloc a Assurez vous que le ro...

Page 20: ...Y EQUIPO DE DETECTCION DE INCENDIOS CO2 ANSI UL 154 ANSI NFPA 12 EXTINCTEUR POUDRE ANSI UL 299 ANSI NFPA 17 EXTINCTEUR EAU ANSI UL 626 ANSI NFPA 13 EXTINCTEUR MOUSSE ANSI UL 8 ANSI NFPA 11 ARROSEURS...

Page 21: ...nt votre commande de 8 00 heures 17 00 heures heure normale de l Est des tats Unis du lundi au vendredi 603 225 6684 Veuillez contacter votre repr sentant agr Pitco Frialator si vous avez des probl me...

Page 22: ...L IMPORTANT FOR FUTURE REFERENCE Please complete this information and retain this manual for the life of the equipment Model ______________________________________ Serial _____________________________...

Page 23: ...salpicadero la cubierta del tanque el estante de trabajo ni el drenaje del equipo Es posible que sufra lesiones graves por resbalarse caerse o entrar en contacto con l quidos calientes ADVERTENCIA NUN...

Page 24: ...ldanas si es el caso con los pernos de cabeza hexagonal que se suministran conelfreidor Cada pata roldana requiere 4 pernos de 1 4 20 x 5 8 c Monte los pernos desde el interior del freidor con la tuer...

Page 25: ...Disconnect Devices for Use with Gas Fuel ANSI Z223 1 Cuando se instale el artefacto para desconexi n r pida tambi n deben instalarse un sistema para limitar el movimiento del freidor Este sistema deb...

Page 26: ...permanentes Los da os causados por corrientes descendentes de aire no est n cubiertos bajo la garant a del equipo NUNCA permita la obstrucci n del flujo de combustible o el de la ventilaci n de salida...

Page 27: ...n de gas a la posici n PILOT y permita que el freidor se caliente por 15 minutos AVISO Nodejeelfreidordesatendidodurantelalimpieza Nuncadejequeelniveldeaguadesciendapor debajo de la marca Min Level e...

Page 28: ...ado Drene el agua en un recipiente adecuado para agua caliente y vi rtala al desag e i Cuando el tanque se haya enfriado enju guelo completamente con agua fr a Contin e enjuagando el tanque hasta que...

Page 29: ...e hasta que los quemadores se prendan a una temperatura de 325 F 163 C Vuelva a colocar la perilla y permita que el freidor realice su ciclo de 4 a 6 veces Verifique la temperatura del term metro cont...

Page 30: ...mostato a la posici n OFF apagado Gire la v lvula de gas a la posici n PILOT El freidor est ahora en Standby y puede mantenerse en estas condiciones por cortos per odos de tiempo NUNCA deje el freidor...

Page 31: ...EQUIPO DE DETECTCION DE INCENDIOS CO2 ANSI UL 154 ANSI NFPA 12 SUBSTANCIA QUIMICA ANSI UL 299 ANSI NFPA 17 AGUA ANSI UL 626 ANSI NFPA 13 ESPUMA ANSI UL 8 ANSI NFPA 11 ROCIADORES ANSI UL 199 ANSI NFPA...

Page 32: ...a las 5 de la tarde Tiempo Est ndar del Este de lunes a viernes 603 225 6684 En caso de problemas o preguntas relativas a su equipo por favor comun quese con el repre sentante de Partes y Servicio Au...

Reviews: