Hunter-Pro Series Captain 8 - Installation Guide
62
8
Key #5: General Parameters
The General system parameters are displayed in three consecutive screens.
8.1.
First screen
Char. Parameter
When s
etting to ‘+’
:
K
State Key Switch
(+): Toggle (ON/OFF) switch
(-): Momentary switch
D
DC Siren
(+): Only DC sirens are connected
(-): Only Bell/Horn sirens are connected
1
TAMPER 1 Connec.
1
TMPR #1 input is monitored
E
TAMPER 1 – EOL
1
TMPR #1 input is EOL resistor loop monitored
2
TAMPER 2 Connec.
1
(+): TMPR #2 input is monitored
(-): TMPR #2 input serves as zone #9 input
E
TAMPER 2 – EOL
1
TMPR #2 input is EOL resistor loop monitored
K
Key-> Home State
Triggering the KEY input will arm the panel to “HOME 1” mode
A
Automatic-> HOME
Automatic arming arms the panel to “HOME 1” mode
B
Byps. Zone in Au.
Open zones are bypassed when the panel is auto-armed (but
will trigger the alarm, if opened).
2
2 EOL Resistors
All EOL resistor loops will monitor for Short and Cut
S
Siren beep in ARM
When arming the panel with a key switch or remote control the
external siren beeps once, and when disarming it, twice see also
parameter “O” in the second screen, next.
M
User Code-> Menu
(+): Entering a User code will display the user menu
(-) : Entering a User code will arm/disarm the panel (toggle)
P
Enhanced Menu
The enhanced communication screens will be displayed
Z
Not in use
-
T
Byps. Tmpr. in Arm
Tamper switches will be bypassed when arming the panel
F
Byps. Fail in Arm
Faults are ignored when arming the panel
Press [ENTR] to save and proceed to the second screen.
8.2.
Second screen
Char. Parameter
When setting
to ‘+’
:
C
Light KP continu
All keypads will illuminate continuously (weakly)
L
Light KP in Alrm
All keypads will illuminate during alarms
D
Light KP in Dely
All keypads will illuminate during the entry/exit delays
1
Not in use in Captain 8.
ENTR
5
Gen. Parameters
ENTER/NEXT/END
KD1E2EKAB2SMPZTF
--+-+--------+++
CLDSF12ZERPFCJAO
+-----+---------