Key #8: Full Programming
69
11
Key #8: Full Programming
See the menu screens from page 97.
11.1.
System defaults
Initialize the system to the factory defaults. This will reset all the data stored in the control panel,
including zone settings and names.
1.
Press [ENTR] -> "Are you sure?"
2.
Press [ENTR] to approve a countdown will start.
3.
Press [END] when the countdown expires.
11.2.
Local download
The “Local Download” is a standby mode for uploading/downloading data via the COMAX
application see section 3.1.2, on page 41, and the COMAX User guide for detailed explanations.
After pressing [ENTR] the panel waits for data packets. Immediately press the “LOCAL” button
in the COMAX.
Wait until “Connected” message is displayed in the COMAX status bar and a beep is sounded you
can now start to upload/download.
11.3.
Fast load
The “Fast Load” is a standby mode for downloading system configuration sets via the PRG-896
fast programmer
1
. The fast programmer can store up to 7 sets for HUNTER-PRO 832 and 4 sets
for 8144. Downloading has 2 set options:
1.
Full set, to download the whole set/s
2.
Communication set, to download only the communication parameters (taken from the
COMAX's "Communication" tab).
11.4.
Installer Code
Set or change the Installer code (default, 1234). The code can have up 4 - 6 digits.
The default code must be replaced immediately after installation!
If the first digit of the code is set to zero, it will not be reset in case
of power loss. This is for security reasons.
1
The sets are uploaded by the COMAX application.
9
Installer Code
ENTER/NEXT/END
ENTR
Installer Code
****** (4-6)