Key #2: Zones
47
5
Key #2: Zones
See the menu screens on page 89.
5.1.
Zone configuration
The available zone types are
Burglary, Panic, Fire, Duress/Hold-Up, Medical, Anti-Mask, Special
Burglary 1, Special Burglary 2, Silent Panic, Special Fire, KeySw Arm, KeySw Home 1 and KeySw
Home 2.
To set the zone type:
1.
On the "Zone Type" screen, enter a zone number or scroll with [*] to the desired zone.
2.
To change the current zone type, press [NEXT] or [BACK] and press [ENTR].
5.1.1.
Zone characteristics
The next table describes the zone characteristics parameter bar.
Char. Parameter
When set to
“+”
this zone…
B
Permanently
bypassed
will be bypassed permanently
Bypassed zones do not trigger the alarm
when opened. Use this feature carefully!
0
Normally Open
“+”: will be wired Normally Open
“-“: will be wired Normally Close
F
24 Hour Zone
will trigger the alarm when opened, regardless of the alarm
system state
H
Active in "Home 1"
will be armed when arming to "Home 1" mode
H
Active in "Home 2"
will be armed when arming to "Home 2" mode
I
Entry Delay
will not trigger the alarm when opened, before the Exit/Entry
delay ends.
D
Zone Follower
will not trigger the alarm if it is open during the Exit delay, as
long as any exit delay zone is still open.
T
Second Delay Time
will not trigger the alarm when opened, before the second
Exit/Entry delay ends.
E
EOL Resistors
will be wired with E.O.L. resistors
P
Conditioned Zone
will not trigger the alarm when opened, unless a coupled zone
is opened too within the “Conditional Zone Time” (see
section 7.8, on page 61).
D
Double Knock
will trigger the alarm only if two pulses occur within a
predefined time.
E
User Bypass
can be temporarily bypassed by the users.
S
Not in use
-
S
Not in use
-
BOFHHIDTEPDE
---+++-----+ 1