Key #4: Timers, Counters
61
7.4.
Phone report delay
Set a time (in minutes) to delay reporting on telephone line faults. Note that if the parameter “No
Dia. tone chck” (see section 6.4, on page 57) is disabled, this parameter is negligible.
If the telephone line is usually clear, do not set a delay time.
7.5.
Burglary report delay
Set a time in seconds (default is zero) to delay reporting on violation of 24-hour zones, if occurred
during the entry delay. The sirens will nonetheless sound the alarm.
This delay is valid to all the burglary alarm types.
If the panel is disarmed before countdown expires, the event will not be reported.
7.6.
Soak test days
Set a number of days (max. 7) that a zone can be in soak (test) mode (see section 13.4, on
page 72). When the test is over, the zone is automatically reinstated.
If set to “0”, the zone is automatically reinstated at midnight of the same day.
The letter “T” indicates the zone is in test, in PIMA display mode.
7.7.
Double knock
Set a time span for “Double knock” zones. If a “Double Knock” zone is tripped continuously and
the “Double knock” timer expires, an ala
rm is set off.
7.8.
Conditioned zones time
Set a time span (in seconds) for conditioned (crossed) zones. Conditioned zones trigger the alarm
only if at least two of them are opened while the timer counts down.
7.9.
Bypass limit time
Set a time limit (in minutes, max. 250) a zone can be manually bypassed, before arming the
system. This is a burglary setup prevention feature.
If the timer expires and the system has not been armed, the zone is automatically reinstated.
7.10.
False code
Set a limit number of keystrokes (default is 24, min. 10, max. 250), when trying to enter a code.
Note that the number refers to the number of keystrokes, and not the number of codes.
When the number is exceeded, the system reports the Monitoring Station and responds according
to the “System Responses” programming (see 9, on page 64).
7.11.
Inactivity report
Set a number of days (250 max, default is zero) during which if the panel has not been armed,
the Monitoring Station is being reported.