Captain-i, Installation Guide
44
Appendix A – Default system parameters
1.
Zones
Zone Definition/
Zone Number
1 2 3 4 5 6
Bypass
- - - - - -
N.O.
- - - - - -
24 hours
- - - - - -
Home
+ + + + + +
Entry Delayed
+ - - - - -
Entry Follower
- + - - - -
End of line
- - - - - -
Siren
+ + + + + +
Communication
+ + + + + +
PGM
- - - - - -
Fire detector
- - - - - -
Sensitivity
8 8 8 8 8 8
Partition
#1
+ + + + + +
Partition
#2
- - - - - -
2.
Codes and delays
To program these parameters, except the Technician Code, enter the Primary Code
and press
. The Technician’s Code is programmed through the Technician Menu.
Primary Code: 5555
User Code #1 to #8: ------
Technician Code: 1234
Short Code: --
Entry Delay: 20 seconds
Exit Delay: 60 seconds
3.
Siren outputs
Siren (Alarm) Time:
240 seconds
SMOKE exit timer:
60 seconds
Siren (Alarm) tones:
0 seconds
4.
System configuration, general parameters
Telephone
(P)
Remote
test (P)
Remote
test (T)
Auto Test
(P)
Auto Test
(T)
Auto
Bypass (B)
+
-
- - - +
Dial Tone
Bypass (T)
Delayed ON
(D)
Zone
Display (Z)
Buzzer with
Siren (B)
Reset by
Zone (R)
Tone
Dialing (T)
- - - - - +