Captain-i - Installation Guide
15
3.1.9
Programming the VU-20N
1.
Navigate to “System config 3” menu (#8) and mark ‘+’ under ‘V - Voice’ unit
and under ‘G - Delayed PGM
2.
In Zone responses menu (#3), click the desired zone and mark ‘+’ under ‘P -
PGM’, so that the zone will trigger the PGM output (to which the VU-20N
connects) in alarm.
Captain-i
V
(+)
AUDIO
IN
VU-20N
GND
(-)
PGM
Blu
e
Re
d
Bl
a
ck
Gr
een
Ye
llow
Loose
3.1.10
GSM-200 Cellular module
OUT
LINE
AUD
IN
O
ra
nge
Yel
lo
w
TRANSMITTER
Captain-i
To connect GSM-200:
1.
Connect the yellow wire to
AUD IN
2.
Connect the orange wire to
AUD OUT
3.1.10.1
Connecting VU-20N with GSM-200 Cellular Transmitter
To connect VU-20N together with GSM-200, connect a 5.1 k
Ω
resistor to one of the
VU-20N blue Audio wires (The second should remain loose).
3.1.11
Mains voltage
Notes:
The cross-section area of the AC main cable must be at least 0.75 mm
2
The hole through which the main cable passes must have either a grommet or
bushing
The wires of the main cable must be tied together with cable tie. The flammability
of the cable tie must be UL 94 V-2 or better
The system should be connected to an automatic circuit breaker that cuts off the
power supply when necessary