Wiring
Operating Manual PSEN sg2c
1003267-EN-04
24
}
The permitted conductor cross section for the connectors is 0.25 - 1.0 mm², 23 - 17
AWG.
}
When calculating the max. cable run, remember to take into account the chapter "Notes
on cable run".
5.4
Terminal configuration
1
X2
3
5
7
9 11 13 15
2
4
6
8 10 12 14 16
1
X1
3
5
7
9 11 13 15
2
4
6
8 10 12 14 16
Terminal
PSEN sg2c-3xxx
PSEN sg2c-5xxxx
PSEN sg2c-5xxxx-
M12/5
X1-1 - X2-1
linked internally
+24 VDC supply voltage
+24 VDC supply voltage
+24 VDC supply voltage
X1-2 - X2-2
linked internally
0 V
0 V
0 V
X1-3
Safety output channel 1
(OSSD1)
Safety output channel 1
(OSSD1)
Safety output channel 1
(OSSD1)
X1-4
Safety output channel 2
(OSSD2)
Safety output channel 2
(OSSD2)
Safety output channel 2
(OSSD2)
X1-5 - X2-5
linked internally
Output pushbutton for ac-
cess request [2]
Output pushbutton for ac-
cess request [2]
Output pushbutton for ac-
cess request [2]
X1-6 - X2-6
linked internally
Solenoid operation (24 V) Solenoid operation (24 V) Solenoid operation (24 V)
X1-7 - X2-7
linked internally
Solenoid operation (24 V) Solenoid operation (24 V) Solenoid operation (24 V)
X1-8 - X2-8
linked internally
Input for activating the
safety gate guard locking
device
Input for activating the
safety gate guard locking
device
Input for activating the
safety gate guard locking
device
X1-9
Signal output for state of
the bolt tongue
Signal output for state of
the bolt tongue
Signal output for state of
the bolt tongue
X1-10
E-STOP 1.1
E-STOP 1.1
E-STOP 1.1
X1-11
E-STOP 1.2
E-STOP 1.2
E-STOP 1.2
X1-12
E-STOP 2.1
E-STOP 2.1
E-STOP 2.1
X1-13
E-STOP 2.2
E-STOP 2.2
E-STOP 2.2