Operation
Operating Manual PSEN sg2c
1003267-EN-04
45
9
Operation
NOTICE
The safety function should be checked after initial commissioning and each
time the plant/machine is changed. The safety functions may only be
checked by qualified personnel.
Teaching in the actuator
}
PSEN sg2c-xxx (coded version)
Any corresponding Pilz actuator (see Technical details) is detected as soon as it is
brought into the response range.
}
PSEN sg2c-xxx 2.2 (uniquely coded version)
The first corresponding actuator to be detected by the safety switch (see Technical de-
tails) is taught in automatically as soon as it is brought into the response range.
NOTICE
Please note: No other actuator may be taught in once an actuator has been
taught.
Status indicators
}
"Device" LED illuminates green: The unit is ready for operation
}
"Safety Gate" LED lights up yellow: Bolt tongue is engaged
}
"Input" LED lights up yellow: Input circuits are closed or a HIGH signal is present
}
"Lock / Area safe" LED illuminates blue: The guard locking element is engaged in the
bolt tongue, guard locking is active. Signals X1-6 and X1-7 (or X2-6 and X2-7) are
present.
}
"Lock / Area safe" LED illuminates green: The guard locking element is engaged in the
bolt tongue, guard locking is active. Signals X1-6 and X1-7 (or X2-6 and X2-7) are not
present.
}
"Lock / Area safe" LED flashes green and blue: Pushbutton 2 for access requirement
was confirmed and the machine stop was requested.