Technical Details Order No. 570806-570810
Operating Manual PSEN sg2c
1003267-EN-04
56
11
Technical Details Order No. 570806-570810
General
570806
570808
570810
Approvals
CE, FCC, TÜV, UL/cUL
CE, FCC, TÜV, UL/cUL
CE, FCC, TÜV, UL/cUL
Sensor's mode of opera-
tion
Transponder
Transponder
Transponder
Coding level in accord-
ance with EN ISO 14119
Low
Low
Low
Design in accordance with
EN ISO 14119
4
4
4
Pilz coding type
Coded
Coded
Coded
Electrical data
570806
570808
570810
Supply voltage
Voltage
24 V
24 V
24 V
Kind
DC
DC
DC
Voltage tolerance
-15 %/+10 %
-15 %/+10 %
-15 %/+10 %
Output of external
power supply (DC)
2 W
2 W
2 W
Max. inrush current at UB
5 A
5 A
5 A
Max. switching frequency
1 Hz
1 Hz
1 Hz
Magnet. supply voltage
24 V
24 V
24 V
Max. solenoid current t
<150 ms
1,5 A
1,5 A
1,5 A
Max. cable capacitance at
the safety outputs
No-load, PNOZ with re-
lay contacts
40 nF
40 nF
40 nF
PNOZmulti, PNOZelog,
PSS
70 nF
70 nF
70 nF
Max. inrush current im-
pulse
Current pulse, A1
5 A
5 A
5 A
Pulse duration, A1
0,0002 ms
0,0002 ms
0,0002 ms
Max. unit fuse protection
in accordance with UL
3 A
3 A
3 A
Inputs
570806
570808
570810
Number
2
2
2
Voltage at inputs
24 V DC
24 V DC
24 V DC
Input current range
5 mA
5 mA
5 mA
Section stop
570806
570808
570810
Number of N/C contacts
2
–
–
Release type
Turn release
–
–