Function description
Operating Manual PSEN sg2c
1003267-EN-04
12
WARNING!
Loss of safety function due to the incorrect installation of the escape re-
lease!
If the escape release pin is accessible from the outside, the guard locking
device can be released from the outside and the safety gates opened, al-
though the hazardous machine is switched on.
Depending on the application, serious injury or death may result.
The escape release should be installed so that it is only accessible from in-
side the danger zone.
It is also important to refer to the maintenance instructions (see chapter en-
titled
Maintenance [
44]
)
INFORMATION
When the escape or auxiliary release is operated, there is a low signal at
the safety outputs X1-3 and X1-4. An error code is issued (see section en-
titled
Remedy [
49]
). The PSENsgate is not ready for operation again
until the escape release or auxiliary release has been reset to its unoper-
ated state and the error has been rectified and reset.
Please note that the cover of the escape release has to be checked and re-
installed after operation.