Installation
Operating Manual PSEN sg2c
1003267-EN-04
37
Fig.: Unlock bolt
6.3
Second installation of safety switch and handle unit /
upgrade for left-hinged gates
}
Remove the screw blocking the spring-loaded limit stop mechanism (see illustration in
previous section "Handle unit and actuator with screw").
}
Uninstall the safety switch from the installation site (compare steps in section en-
titled
Initial installation of safety switch [
31]
in reverse order).
}
Uninstall handle unit from the gate. To do this, position the screwdrivers in the slots
provided on the limit stop mechanism (see graphic "Unlock bolt").
}
Press screwdriver towards the base plate to release the spring-loaded limit stop mech-
anism.
}
Disengage bolt tongue with handle unit in the actuator guide.
}
Remove exposed fixing screws.
}
Unscrew ball handle from the handle unit.
}
Remove the cover of the handle unit from the bolt tongue (2 countersunk screws).
}
Take limit stop from the bolt tongue and insert it from the other side into the location
hole.
}
Turn bolt tongue around its longitudinal axis and screw together with the cover of the
handle unit.
}
Carry out the steps from the sections entitled
Initial installation of handle unit [
36]
and
Initial installation of safety switch [
31]
.
6.4
Labelling the pushbuttons
Colour covers are supplied with the PSEN sg2c Unit; these must be attached to the push-
buttons, based on their function (see also order references for
Accessories [
85]
).
}
Press the colour covers into the pushbuttons in accordance with the required function.
The colour covers lock into position on the pushbuttons.