OPERATIONAL POP-UP WINDOWS

Operational pop-up windows have a grey color and 
appear in the middle of the work screen. They appeal 
to  the  user  for  deciding  on  the  continuation  of  the 
process.  After  taking  the  decision,  the  window  will 
disappear.

If the material is used up, the operator is informed via 
this window. After pressing the OK button, the fixed 
vice is released. The system switches to the default 
screen of the NC mode. Now there is the option to 
switch the machine to manual mode and cut the rest 
of the material manually, or insert new material and 
start  the  cycle.  Cycle  will  resume  where  it  ended. 
Before  continuing  the  cycle,  you  can  choose 
downcutting and align new material.

FAILURE POP-UP WINDOWS

Failure pop-up windows have a black color and appear in the middle of the work screen. 
They inform the user about malfunction. The failure is immediately recorded in the error 
status on the Failures screen. Execute the cancellation of the pop-up window after solving 
the failure, by clicking in the area of the pop-up window.

Under  the  main  announcement,  status  of  sensors  for  easy  detection  of  failures  may 
appear: 
BP - Limit switch
TS - Pressure switch
Blue square signalizes that the device is switched on.
More about failure reporting in chapter Failures.

PERFORM 

KERF?

NO

YES

INFORMATIONAL POP-UP WINDOWS

Informational pop-up windows have a blue color and appear in the middle of the work 
screen. They inform the users about the status changes or about non-failure conditions.

List of information windows:
The number of series is greater than 10

 - indicates that the number of active series 

exceeded the amount that can be displayed on the screens of the Main menu, NC mode, 
Performing series and Series interrupted.

Insert the material

 - informs you that the material has not been inserted.

Material will be shortly used up. Prepare new

 - informs that the material will soon have 

been cut. In order to continue the series, it is necessary to prepare new material.

Performing downcutting

 - informs that the machine performs downcutting of the ends of 

the inserted material. Replace battery in the PLC. Charge is less than 50% 

- indicates 

that the backup battery is at the end of service life and should be replaced with a new one. 
Designation of the battery by Schneider Electric: TSXPLP 01.

FAILURE TS

Pressure sensor

fixed vice

(right-R)

%IX0.3   BP7

%IX0.6   TS2

Replace the

battery in the 

PLC.

Charge is less

than 50%.

Material ending.

Load new material

Press OK to open fixed vice

OK

Summary of Contents for ARG 260 CF-NC automat

Page 1: ...G 300 DCT CF NC automat ARG 330 CF NC automat ARG 330 DC CF NC automat ARG 520 DC CF NC automat 1 PART INSTRUCTION MANUAL Pilous p sov pily spol s r o elezn 9 619 00 Brno Czech Republic tel 00 420 543...

Page 2: ......

Page 3: ...ction 1 2 Packing 1 3 Disassembly Repacking 1 4 Disposal 2 Technical Data 3 Installation 3 1 Space Requirements 3 2 Removal of Temporary Transport Beams and Fixation of the Machine 3 3 Machine Install...

Page 4: ...r any other inappropriate environment Wear parts see the Letter of Guarantee Potential claims concerning guarantee and after guarantee repairs should be made by phone post or e mail to the address see...

Page 5: ...or and secure it against restart before you start handling the saw blade Only persons with adequate electrician qualifications are allowed to open protective covers of the electrical equipment and to...

Page 6: ...raps to prevent movement Thread the straps through the yellow consoles located in the corners of the machine see picture It is recommended to transport and lift the machine only with a forklift Forks...

Page 7: ...3 kW Hydraulic oil approx 26 l 1450 kg 2560 2220 2080 850 mm 3 approximately 35 litres 90 60 60 45 45 400 V 50 Hz 550 W ARG 520 DC CF NC 180 170 180x120 3150x27x0 9 355 mm 300 285 205x290 Hydraulic o...

Page 8: ...or near the working area of the machine No unauthorised personnel may enter the danger zone To prevent injury the danger zone must also be level and free from any foreign objects and obstacles Recomm...

Page 9: ...F NC ARG 300 DCT CF NC ARG 330 CF NC ARG 330 DC CF NC ARG 520 DC CF NC ARG 260 CF NC A max B max C max 1330 mm 1790 mm 2215 mm 2370 mm 2280 mm 2980 mm 2970 mm 2970 mm 2970 mm 2970 mm 2970 mm 2660 mm 1...

Page 10: ...n temperatures below 5 C the conventional coolants should be replaced by coolants designed for respective temperatures In addition to that replace the oil in the hydraulic unit for a less viscous one...

Page 11: ...e C saw blade tensioning D gearbox E motor F fixed vice G movable vice H base I arm J control panel K table L chip tray M fixed bar N movable bar O hydraulic cylinder of the vice P hydraulic cylinder...

Page 12: ...gearbox E motor F fixed vice G movable vice H base I arm J control panel K table L chip hopper chip bin M cleaning brush N fixed bar O movable bar P hydraulic cylinder of the vice Q hydraulic stroke c...

Page 13: ...J S ARG 520 DC CF NC automat C A D E F G H K L M N O P Q R S T W X...

Page 14: ...controlled hydraulically The servo motor and the ball screw ensure high speed and maximum accuracy of material feeding Maximum length of a single feed is 500 mm in ARG 520 DC CF NC 600 mm The control...

Page 15: ...ting LAMP 24 V Indicator lamp indicates that the CONTROL PANEL is under power supply of 24 V You can change the cutting speed using a saw blade speed controller using a frequency converter on the cont...

Page 16: ...ction manual because they possess the same function on all screens After you press the TIME box a screen with data about the operating status of the machine appears applies to all screens in all modes...

Page 17: ...rview of the active series Hydraulic unit Start Stop Press the hydraulic unit START STOP icon to start or stop the hydraulic unit START Starting the automatic cycle After pressing the START button the...

Page 18: ...press the START button of the WORKING CYCLE in the SEMI AUTOMATIC MODE to perform the cycle After finishing the vice remains open If the vice is closed press the START button of the WORKING CYCLE in t...

Page 19: ...different function that has not been activated yet the button of the preceding function will start flashing to indicate error START STOP uplift or descent of the arm Saw blade upwards Saw blade downw...

Page 20: ...s it is possible to set up the following series without interrupting the cycle If the editing of the next series takes too long and the machine completes the previous series in the meantime cutting of...

Page 21: ...g it while feeding the material by the set value After finishing the cut the vice will feed the material by the set value If it is no longer possible to feed the material towards 0 mm the vice move ag...

Page 22: ...SERIES X 12 Clearly displays the complete status and a list of all series SERIES LIST 1 2 0 9 2 0 0 3 0 8 1 0 2 0 1 6 ESC SERIES LENGTH PIECES FEED ACT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 357 159 456...

Page 23: ...ess the DATE SETTING button to enter the specified date into the system MACHINE SETUP LANGUAGE switch to the screen selection of several languages UNIT possibility of setting the unit length in mm or...

Page 24: ...ars on top and is not deleted In the case of a new failure the previous failure will move to a line below The system stores 200 failures You can browse through the list using buttons Failures appear i...

Page 25: ...is between two Faston connectors to the right Such operations may be carried out only by persons with electrician qualifications Danger of short circuit of 24V contacts Release the right vice If the...

Page 26: ...t height settings If the current position of the arm does not correspond to a check measurement by a gauge tape measure carry out the calibration of arm uplift position measurement 1 Input 0 in the co...

Page 27: ...witch TS Pressure switch Blue square signalizes that the device is switched on More about failure reporting in chapter Failures PERFORM KERF NO YES INFORMATIONAL POP UP WINDOWS Informational pop up wi...

Reviews: