background image

FINISHED

After completing all of the series (or after terminating the currently 
performed  series  using  the  Stop  button),  the  screen  displays 
FINISHED.  After  pressing  OK,  the  system  goes  back  to  the 
default  screen  of  the  automatic  mode.  The  machine  does  not 
switch  to  the  primary  position  because  of  the  possibility  of 
continuing with other series without downcutting of the material.

If you need to exchange the material, press the button PRIMARY 
POSITION.   After the machine switches to the primary position, 
the vices will be released.

After a long time of inactivity on this screen, the machine will go to 
sleep  -  the  hydraulic  unit  automatically  shuts  down.  You  can 
activate it again by pressing the OK button.

Note:  After  successful  completion  of  the  series,  the  series 
switches itself off. In the case of a request to cut the same series, 
it is necessary to turn it back on.

4.1.6. Side menu

TIME + DATE SETTING

The  screen  TIME+DATE  SETTINGS  get  activated  after 
pressing  the  button  TIME+DATE  on  the  MACHINE  SET

UP

 

screen.

Input the current time in dark grey boxes in the red-outlined 
box. After you input the time, press the 

TIME 

SETTING

 

button 

to enter the set time into the system.

Input the current date in dark grey boxes in the red-outlined 
box. After the input, you have to press the 

DATE

 SETTING

   

button to enter the specified date into the system.

MACHINE SETUP

LANGUAGE 

–  switch  to  the  screen,  selection  of  several 

languages.

UNIT

 - possibility of setting the unit length in mm or in inches

KERF

 - setting of the kerf, i.e. the value, which the saw blade cuts 

through the material. The system includes this value in the feed as 
well. The  correct  setting  is  important  particularly  in  the  case  of 
multiple feeds

SERVO SPEED 

- possibility to set the feed speed 

1

 - 3,0 m/min, 

2

 - 

2,5 m/min, 

3

 - 1,6 m/min

BUNDLE-CUTTING  HVP

  -  if  the  upper  thrust  is  installed 

(accessory), its function must be enabled (green tick)

EMULSION/OIL  MIST 

-  you  can  switch  between  cooling  by 

coolant (red cross) or oil mist (accessories) (green tick)

PRESSURE SWITCHES

 - switch to the screen with vice pressure 

switch settings

TIME + DATE

 - switch to the screen with system date and time 

settings

SYSTEM

 - switch to the system settings screen with converters, 

servo  motors,  PLC  settings.  The  screen  is  locked  -  only  the 
manufacturer or the distributor can edit the data.

WORM CHIPS TRANSPORTER

 - switch to a service screen for 

maintenance and cleaning of the machine

FINISHED

0 9 : 2 0 : 0 3

0 8 / 1 0 / 2 0 1 6

OK

Total time:  123  min

MACHINE SETUP

0 9 : 2 0 : 0 3

0 8 / 1 0 / 2 0 1 6

SYSTEM

BUNDLE-

CUTTING HVP

EMULSION / 

OIL MIST

PRESSURE

SWITCHES

TIME+DATE

LANGUAGE

UNIT

KERF

SERVO

SPEED 

0 HOU.

OPERATING 

HOURS

ESC

(mm)

1.12

1

TIME + DATE SETTING

0 9 : 2 0 : 0 3

0 8 / 1 0 / 2 0 1 6

0

0

0

0

0

0

TIME

SETTING

DATE

SETTING

H

M

S

DD

MM

YYYY

ESC

Summary of Contents for ARG 260 CF-NC automat

Page 1: ...G 300 DCT CF NC automat ARG 330 CF NC automat ARG 330 DC CF NC automat ARG 520 DC CF NC automat 1 PART INSTRUCTION MANUAL Pilous p sov pily spol s r o elezn 9 619 00 Brno Czech Republic tel 00 420 543...

Page 2: ......

Page 3: ...ction 1 2 Packing 1 3 Disassembly Repacking 1 4 Disposal 2 Technical Data 3 Installation 3 1 Space Requirements 3 2 Removal of Temporary Transport Beams and Fixation of the Machine 3 3 Machine Install...

Page 4: ...r any other inappropriate environment Wear parts see the Letter of Guarantee Potential claims concerning guarantee and after guarantee repairs should be made by phone post or e mail to the address see...

Page 5: ...or and secure it against restart before you start handling the saw blade Only persons with adequate electrician qualifications are allowed to open protective covers of the electrical equipment and to...

Page 6: ...raps to prevent movement Thread the straps through the yellow consoles located in the corners of the machine see picture It is recommended to transport and lift the machine only with a forklift Forks...

Page 7: ...3 kW Hydraulic oil approx 26 l 1450 kg 2560 2220 2080 850 mm 3 approximately 35 litres 90 60 60 45 45 400 V 50 Hz 550 W ARG 520 DC CF NC 180 170 180x120 3150x27x0 9 355 mm 300 285 205x290 Hydraulic o...

Page 8: ...or near the working area of the machine No unauthorised personnel may enter the danger zone To prevent injury the danger zone must also be level and free from any foreign objects and obstacles Recomm...

Page 9: ...F NC ARG 300 DCT CF NC ARG 330 CF NC ARG 330 DC CF NC ARG 520 DC CF NC ARG 260 CF NC A max B max C max 1330 mm 1790 mm 2215 mm 2370 mm 2280 mm 2980 mm 2970 mm 2970 mm 2970 mm 2970 mm 2970 mm 2660 mm 1...

Page 10: ...n temperatures below 5 C the conventional coolants should be replaced by coolants designed for respective temperatures In addition to that replace the oil in the hydraulic unit for a less viscous one...

Page 11: ...e C saw blade tensioning D gearbox E motor F fixed vice G movable vice H base I arm J control panel K table L chip tray M fixed bar N movable bar O hydraulic cylinder of the vice P hydraulic cylinder...

Page 12: ...gearbox E motor F fixed vice G movable vice H base I arm J control panel K table L chip hopper chip bin M cleaning brush N fixed bar O movable bar P hydraulic cylinder of the vice Q hydraulic stroke c...

Page 13: ...J S ARG 520 DC CF NC automat C A D E F G H K L M N O P Q R S T W X...

Page 14: ...controlled hydraulically The servo motor and the ball screw ensure high speed and maximum accuracy of material feeding Maximum length of a single feed is 500 mm in ARG 520 DC CF NC 600 mm The control...

Page 15: ...ting LAMP 24 V Indicator lamp indicates that the CONTROL PANEL is under power supply of 24 V You can change the cutting speed using a saw blade speed controller using a frequency converter on the cont...

Page 16: ...ction manual because they possess the same function on all screens After you press the TIME box a screen with data about the operating status of the machine appears applies to all screens in all modes...

Page 17: ...rview of the active series Hydraulic unit Start Stop Press the hydraulic unit START STOP icon to start or stop the hydraulic unit START Starting the automatic cycle After pressing the START button the...

Page 18: ...press the START button of the WORKING CYCLE in the SEMI AUTOMATIC MODE to perform the cycle After finishing the vice remains open If the vice is closed press the START button of the WORKING CYCLE in t...

Page 19: ...different function that has not been activated yet the button of the preceding function will start flashing to indicate error START STOP uplift or descent of the arm Saw blade upwards Saw blade downw...

Page 20: ...s it is possible to set up the following series without interrupting the cycle If the editing of the next series takes too long and the machine completes the previous series in the meantime cutting of...

Page 21: ...g it while feeding the material by the set value After finishing the cut the vice will feed the material by the set value If it is no longer possible to feed the material towards 0 mm the vice move ag...

Page 22: ...SERIES X 12 Clearly displays the complete status and a list of all series SERIES LIST 1 2 0 9 2 0 0 3 0 8 1 0 2 0 1 6 ESC SERIES LENGTH PIECES FEED ACT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 357 159 456...

Page 23: ...ess the DATE SETTING button to enter the specified date into the system MACHINE SETUP LANGUAGE switch to the screen selection of several languages UNIT possibility of setting the unit length in mm or...

Page 24: ...ars on top and is not deleted In the case of a new failure the previous failure will move to a line below The system stores 200 failures You can browse through the list using buttons Failures appear i...

Page 25: ...is between two Faston connectors to the right Such operations may be carried out only by persons with electrician qualifications Danger of short circuit of 24V contacts Release the right vice If the...

Page 26: ...t height settings If the current position of the arm does not correspond to a check measurement by a gauge tape measure carry out the calibration of arm uplift position measurement 1 Input 0 in the co...

Page 27: ...witch TS Pressure switch Blue square signalizes that the device is switched on More about failure reporting in chapter Failures PERFORM KERF NO YES INFORMATIONAL POP UP WINDOWS Informational pop up wi...