22
Operation
Reset -
Pressing this button will reset a stalled bottle or missing foil fault condition as long as the
fault no longer exists.
Run/Setup -
Pressing this button will toggle between the run and setup mode for the stalled
bottle detector. The setup LED will light when in the setup mode.
Power Setting
It may be known from previous experience what power setting should be used to seal a particular
cap at a known time or conveyor speed. However, one should always test the setting before
running to assure that good sealing occurs.
Setup and Operation with Conveyor Coil:
1. Determine the necessary speed of the conveyor. An increase in conveyor speed will
reduce the amount of heat developed in each seal. A proportional increase in power
supply output will be required to maintain seal quality. Once this speed is decided and
set, it must remain constant.
2. Ensure that the coil is properly mounted and positioned on the conveyor.
3. Set the Alarm setting to "00" or some low setting. Set the power level at some arbitrary
value (such as 50%). For the conveyor coil press the start button, then place a bottle onto
the conveyor and let it run under the coil.
4. Retrieve the bottle and allow a few seconds for it to cool. Remove the cap and inspect
the seal. The foil must be completely sealed around the lip of the bottle, without melting
into the lip. Also, the wax must release from the foil.
5. Adjust the power level up or down as needed and test a new bottle. Repeat with a new
bottle each time until a satisfactory seal is obtained.
Summary of Contents for UniFoiler 3000
Page 10: ...4 Introduction This page left blank...
Page 19: ...Installation 13 This page left blank...
Page 24: ...18 Setup This page left blank...
Page 30: ...24 Operation This page left blank...
Page 36: ...30 Service Dimensions Figure 8 Coil Support Dimensions...
Page 37: ...Service 31 Figure 9 Enclosure Dimensions Figure 10 Internal Components...