127
the modulating signal is at +5v, and the output will be at the minimum
amplitude when the modulating signal is at-5v.
AM:SOURce?
Query the modulating source in amplitude modulation. “INT” or “EXT” string
indicating the modulating source will be returned.
AM:STATe {OFF|ON}
Disable or Enable the amplitude modulation. The default is OFF.
To avoid multiple waveform changes, you can enable AM after setting the
modulation parameters.
AM:STATe?
“0” (OFF) or ”1” (ON) will be returned.
APPLy:
SINusoid [<frequency> [,<amplitude > [,<offset>] ]]
Output a sine wave with specific frequency, amplitude and offset. The waveform
is output as soon as the command is executed.
APPLy:
SQUare [<frequency> [,<amplitude > [,<offset>] ]]
Output a square wave with specific frequency, amplitude and offset. The duty
cycle is set automatically to 50%. The waveform is output as soon as the
command is executed.
APPLY:
RAMP [<frequency> [,<amplitude > [,<offset>] ]]
Output a ramp wave with specific frequency, amplitude and offset. The
symmetry is set automatically to 100%. The waveform is output as soon as the
command is executed.
APPLY:
PULSe [<frequency> [,<amplitude > [,<offset>] ]]
Output a pulse wave with specific frequency, amplitude and offset. The
waveform is output as soon as the command is executed. This command works
with the current edge time setting and the current duty cycle or pulse width