background image

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and 

properly maintained, give you years of trouble free performance.

  1.  SAFETY INSTRUCTIONS

IMPORTANT:

 

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS. 

USE THIS PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE 

AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

INSTRUCTIONS FOR:

PORTAbLE GENERATORS

 

WARNING!

 

Ensure any Health & Safety, Government, or local authority regulations are adhered to when using this equipment. 

  Familiarise yourself with the application and limitations, as well as the potential hazards, of the generator.

 

Maintain the generator in good condition (use an authorised service agent). Replace or repair damaged parts. Use genuine parts only.  

 

  Unauthorised parts may be dangerous and will invalidate the warranty.

  This generator is designed and manufactured for specific applications. Do not attempt to modify the unit or use it for any application for    

  which it is not designed. If you have any questions regarding the application of the unit please contact your local Sealey dealer.

 

WARNING! DO NOT exceed the Wattage/Amperage capacity of the generator.

 Add rated wattage of all devices intended for connection  

  at any one time, the total must not exceed rated wattage of generator (see specifications). 

 

WARNING! Generator exhaust gases contain deadly carbon monoxide which must not be inhaled. Always allow sufficient  

 

  ventilation.

 

WARNING! If you decide to use an Earth Leakage Circuit breaker (also referred to as an RCD or Ground Fault Circuit Interrupter),

  it is imperative that the neutral end of the power winding is connected to the frame of the generator set and that the earth lug on  

  the frame is connected with a low impedance connector to the local earth via an earth spike or local protective earth conductor.   

  This connection should only be attempted by a qualified electrician, after first having consulted your local dealer.

 

DANGER! This generator is designed for outdoor use only. To use the generator inside any building or enclosure, including the 

  generator compartment of a caravan, may result in fire or an explosion. No user performed modifications, including venting of 

  the exhaust and/or cooling ventilation, will eliminate the danger.

 

DANGER!  If this unit is used for back-up power in the event of a commercial power failure, the following steps must be taken.

  before connecting the generator to the electrical system, open the main circuit breaker to isolate the generator and system from  

  the commercial electric supply. Failure to do this may result in damage to the generator and may result in serious injury or  

 

  fatality, due to a back-feed of electrical energy.

 

DANGER! The generator produces a very powerful voltage that can cause a severe electrical shock. Avoid contact with bare 

  wires, terminals etc. Never allow any unqualified person to operate or service the generator.

 

WARNING! Petrol is highly flammable and petrol vapour is explosive. Do not permit smoking, naked flames, sparks or heat in the

   vicinity while handling petrol. Avoid spilling petrol onto a hot engine. Comply with all laws regulating storage and handling of    

  fuels.

 

WARNING!  NEVER refuel when the engine is running or when the engine is hot. Allow cool down time.

 

Operate the generator only on level surfaces (maximum allowable tilt is 10º) and where it will not be exposed to excessive moisture, dirt    

  or corrosive vapours or be in the proximity of combustible material (flammable liquids, solids or gases). 

 

Remove ill fitting clothing, ties, watches, rings and other loose jewellery and contain long hair. Wear appropriate protective clothing.

 

Keep non-essential persons away from the working area.

 

WARNING! Never start or stop the generator while electrical loads are connected. Start the engine, let it stabilise, then connect    

  the electrical load. To stop engine, disconnect the electrical load and let engine stabilise before switching off.

 

WARNING! Do not use worn, bare, frayed or otherwise damaged electrical cables with the generator. To do so may result in  

 

  electric shock.

 

DO NOT

 use the generator for any purpose other than that for which it is designed. 

 

DO NOT

 operate the generator if any parts are missing or damaged, as this may cause failure and/or personal injury.

 

DO NOT

 over-fill fuel tank. Always leave room for fuel to expand.

 

DO NOT

 operate in the rain.

 

DANGER! Do not tamper with the engine governed speed setting. Higher operating speeds are dangerous and increase the risk   

  of personal injury and/or equipment damage. The generator supplies the correct rated frequencies and voltage only when  

 

  running at the correct governed speed. Incorrect frequency and/or voltage can damage some connected electrical loads.  

 

  Operating at excessively low speeds may result in shortened engine life. Over-speeding will invalidate the warranty.

 

DO NOT

 operate the generator when you are tired, or under the influence of alcohol, drugs or intoxicating medication.

 

DO NOT

 store generator with fuel in tank where petrol vapours might reach an open flame or spark.

MODELS:

GG1100

GG2800

GG3800

GG7500

Original Language Version

GG1100, GG2800, GG3800, GG7500    Issue: 2 - 12/10/09

Summary of Contents for GG1100

Page 1: ...t be taken Before connecting the generator to the electrical system open the main circuit breaker to isolate the generator and system from the commercial electric supply Failure to do this may result in damage to the generator and may result in serious injury or fatality due to a back feed of electrical energy DANGER The generator produces a very powerful voltage that can cause a severe electrical...

Page 2: ... DO NOT run this generator unless there is adequate ventilation the exhaust gases contain deadly carbon monoxide 3 4 1 Ensure you have performed all actions in paragraphs 3 2 and 3 3 above 3 4 2 Turn the fuel valve to the ON position Fig 1 3 4 3 Move the choke lever to the CHOKE position Fig 2 Note If starting a warm engine or when the ambient temperature is high move the choke control to the RUN ...

Page 3: ... the oil has drained replace the drain plug 5 1 4 Refill with SAE 10W 30 oil 5 1 5 Replace dipstick 5 2 Air Filter 5 2 1 Remove screws GG1100 Fig 7 or clips on other models and remove the air filter cover 5 2 2 Remove the foam element from the air filter assembly Fig 8 5 2 3 Wash out the element using paraffin and dry thoroughly 5 2 4 Dip the element into clean machine oil and remove excess oil 5 ...

Page 4: ...ed Clean or replace spark plug Incorrect starting technique Read section 3 4 5 for correct technique No power generated Circuit breaker in OFF position Reset to ON Incorrect voltage selected Set switch to correct voltage excluding GG1100 Fig 9 Float Chamber Foam Element Cover Screws Fig 8 Fig 7 Fig 10 NOTE It is our policy to continually improve products and as such we reserve the right to alter d...