OPERATING AND INSTALLATION INSTRUCTIONS LG 250 A
PAGE 31
U
S
ER
G
ENER
A
L
S
P
EC
IA
LIS
T
P
ER
S
O
NNEL
Changes reserved
To ensure safe operation of the system,
safety devices and covers must not be
rendered inoperative; nor may measures
be taken to bypass or dismantle them.
The system must be taken out of
operation immediately in the event of any
fault or damage to the ventilation unit that
may cause harm to persons or property.
Further use must be actively prevented
until the unit is fully repaired! The unit
may only be restarted by a specialist
installer.
Overheating protection:
A thermo-bimetal switch is built
into the optional, integrated frost
protection heater or the optional
reheater battery to protect against
overheating. If a temperature of +50 °C
is reached, power supply to the electric
battery is interrupted and the anti-freeze
heating is switched off .
SAFETY DEVICES
With mechanically-controlled residential
ventilation, used, damp extract air is
conducted away from wet domestic areas,
e.g. bathroom, toilet and kitchen, and
is replaced with fresh, processed and
fi ltered outdoor air in lounge areas e.g. in
living rooms and bedrooms.
Signifi cant energy savings are achieved
when the system is operated continuously
thanks to highly effi
cient heat exchangers
for heat recovery from extract air and
use of energy-effi
cient fans with the
latest DC technology for air fl ow control.
This technology is particularly eff ective
in air-tight building shells and with
active thermal insulation. A temperature
change rate of up to 84.7 % heat recovery
provides highly effi
cient energy savings.
It must in particular be ensured that the
heat exchanger is protected against frost
by means of an appropriately adjusted
frost protection strategy, and that eff ective
condensate drainage is ensured.
12. Functionality of the ventilation system
SYSTEM DESCRIPTION
A
1
2
3
C
E
1
D
2
3
B
7
A
E
IN
B
A
U
V
O
R
S
C
H
L
A
G
C
4
4
5
6
7
E
D
5
6
B
Benennung:
Datum:
Gezeichnet:
Kunde:
Blatt Nr.
Dateiname:
Maßstab:
DIESER PLANUNGSVORSCHLAG IST NUR IN VERBINDUNG MIT UNSEREN VORBEMERKUNGEN GÜLTIG!
BEHÖRDENAUFLAGEN SIND BAUSEITIG ABZUKLÄREN UND UNBEDINGT EINZUHALTEN!
NATURMASZE UND HÖHENKOTEN SIND ZU ÜBERPRÜFEN!
UNSTIMMIGKEITEN SIND MIT DEM PLANVERFASSER ABZUKLÄREN!
ALLE MASZE SIND VOR DER AUSFÜHRUNG VOM KUNDEN ZU PRÜFEN!
Geprüft:
Diese Zeichnung stellt
nach
den Urh. Ges § 24 unser geistiges Eigentum
dar und darf ohne unsere ausdrückliche Zustimmung weder Konkurrenzfirmen,
noch dritten Personen weitergegeben werden. Die unbefugte bzw. bestimmungswidrige
Verwendung dieser Unterlagen ist nicht gestattet und wird gerichtlich verfolgt.
Baugruppe E-Vorheizregister LG250
LG250 E-Vorheizregister 01 seite 18.idw
21.01.2009
WRoth
Prüfer:
1 von 1
1 : 5
Freimaßtoleranz nach DIN ISO 2768-mH
Zeichnungsstatus: Freigegeben
Revision:
-
Gespeichert: 10.04.2017 09:04:56
Bauvorhaben:
Gewicht:
1,188 kg
Auftragsnummer:
J. Pichler Gesellschaft m.b.H
9021 Klagenfurt, Karlweg 5, Postfach 32
T +43 (0)46332769, F +43 (0)463 37548
[email protected], www.pichlerluft.at
wroth
30.11.2016
Zeichnungsnummer:
Artikelnummer.
40LG250BG320
PTC-Niedertemperaturregister mit
Schutzabdeckung
Thermo-Biemetallschalter
optionales PTC-Niedertemperatuur-
Heizregister-Einheit für Frostschutz
PTC low temperature battery
with protective cover
Thermo-bimetal switch
Optional PTC low temperature
heater battery unit for frost protection