For the system venting during the circuit filling step, there is a special union at the top of the head (see
filling rules).
To ensure cooling in case of poor dynamic ventilation, there is an electric fan controlled by the injection
system.
TECHNICAL SPECIFICATIONS
Specification
Desc./Quantity
Cooling system capacity
1.7 l
Prescribed fluid
Mixture of 50% water and fluid for sealed circuits (PARAFLU
MOTO RIDER)
Sealing pressure
Cap calibrated at 0.9 bar
THERMOSTAT
Specification
Desc./Quantity
Type
Wax-type, with deviator
Starts opening
82 ± 2°C
ELECTRIC VENTILATION
Specification
Desc./Quantity
Type
With piston
Electric ventilation starts at
107°C
Electric ventilation stops at
103°C
WATER PUMP
Specification
Desc./Quantity
Type
Centrifugal
Control
Coaxial at the countershaft
RADIATOR
Specification
Desc./Quantity
Type
Aluminium, with horizontal circulation
EXPANSION TANK
Specification
Desc./Quantity
Calibration
Automatic bleeding, in parallel with the radiator
Electric fan check
- Connect the injection diagnostic tester and select
the «ERRORS» function in this menu.
- Check any failures in the electric fan control cir-
cuit (see «Injection»chapter)
Specific tooling
020680Y
Diagnosis Tool
Beverly 500 i.e.
Cooling system
COOL SYS - 303
Summary of Contents for Beverly 500 i.e.
Page 1: ...WORKSHOP MANUAL 633387 Beverly 500 i e...
Page 5: ...INDEX OF TOPICS CHARACTERISTICS CHAR...
Page 17: ...INDEX OF TOPICS MAINTENANCE MAIN...
Page 32: ...INDEX OF TOPICS ELECTRICAL SYSTEM ELE SYS...
Page 51: ...INDEX OF TOPICS ENGINE FROM VEHICLE ENG VE...
Page 54: ...INDEX OF TOPICS ENGINE ENG...
Page 162: ...Countershaft fixing nut 25 29 Engine Beverly 500 i e ENG 162...
Page 163: ...INDEX OF TOPICS INJECTION INJEC...
Page 260: ...INDEX OF TOPICS SUSPENSIONS SUSP...
Page 284: ...INDEX OF TOPICS BRAKING SYSTEM BRAK SYS...
Page 301: ...INDEX OF TOPICS COOLING SYSTEM COOL SYS...
Page 310: ...INDEX OF TOPICS CHASSIS CHAS...
Page 329: ...INDEX OF TOPICS PRE DELIVERY PRE DE...
Page 333: ...INDEX OF TOPICS TIME TIME...